Test mode
Test mode.
The Test mode is indicated by flickering DMX LED(s) and the blinking
Test / Error LED.
7.1

Test mode via Test button

The Test button allows to test the connected DMX devices directly with the
e:cue Bridge8.
Keep the Test button pressed for about 5 seconds until the DMX 1
LED flickers and the Test / Error LED flashes in the short-short-long
sequence. Releasing the button now starts the Test mode at the first
DMX port with blinking lights of all channels (test pattern 1).
Short-press the Test button to switch to chasing lights at intervals
of 96 channels (pattern 2).
Short-press the Test button to switch all channels to 100%
(pattern 3).
Short-press the Test button to switch all channels off (pattern 4).
Short-press the Test button to alternate between the individual
DMX ports and the four test patterns. After the individual test of the
DMX port 8, all DMX ports are tested simultaneously. Another short-
press starts the test patterns from the beginning.
To exit the Test mode at any time, keep the Test button pressed for
5 seconds. The device proceeds to normal operation. The DMX LEDs
no longer flicker and the Test / Error LED is off.
7.2

Test mode via web interface

The web interface of the e:cue Bridge8 provides four different test patterns
and allows to change their properties.
To access the web interface, open a common web browser on a connected
PC. Enter the e:cue Bridge8's IP address into the address bar:
e.g. http://192.168.123.1.