Output configuration
Repeat the following steps for each source:
2.
At the top, select a protocol type (Art-Net, sACN) from the drop
down menu and click the "configure" button. In the protocol
configuration, configure the source protocol parameters e.g. the IP
address accordingly. Click the "submit" button to save the protocol
configuration.
3.
Enter the connected fixture's universe at the source universe ("Src
Universe").
Additionally an offset within this universe can be specified ("Start
Address").
It is possible to map the same universe to multiple ports. This means
you can duplicate content using the e:cue Bridge8.
4.
After configuring all ports, click the "submit" button to save the
configuration.
6.3
Source switch
The third step of the output configuration is to configure the source that
defines the switching between Source 1 and Source 2. The value of the
switch source will be taken to do a fade out / fade in between the two input
sources:
Light intensity
100 %
24
Source 1
0 %
0
128
Source 2
DMX input
(channel value)
255