General device description
2.3

User interface: LEDs

The e:cue Bridge8 has 11 LEDs on the front panel. The 11 LEDs show the
basic states of the e:cue Bridge8.
LEDs
Status
Ethernet
Test / Error
DMX 1 ... 8
12
On: If constantly on, the device is online. Server
application is in operation.
Blinking: If blinking in one second intervals, the
device is offline. If blinking more rapidly, the device is
in bootloader mode.
Off: no link available.
On: link established.
Blinking: Ethernet traffic.
Off: no error detected.
Short-short-long sequence: Test mode active.
On: If constantly lights in red, an error occurred. This
can be an internal error or malfunction of the device,
or an external error, e.g. a shortcut of interface
connections or alien power supply. Switch the device
off and on. If the error persists, check the wiring or
contact OSRAM Service.
Orange: DMX data.
Orange + White: port error.