Herunterladen Inhalt Inhalt Diese Seite drucken

Protective Earth - OSRAM e:cue Bridge8 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation
To connect the device to a power supply unit, use the provided 2-pole
terminal and lay the wires as stated on the front label. The voltage
assignment is left V+ and right V-.
Turn the power on when all cables are connected to the e:cue Bridge8. The
device starts booting. During the booting process all DMX LEDs turn on
consecutively. The device has finished booting and is in operation when the
LED Status is flashing.
i
The e:cue Bridge8 is not suited for powering over a DC
power supply network. Use a separate certified SELV Class
2 power supply unit in the control cabinet for supplying 24 V
DC to the e:cue Bridge8.
4.6

Protective Earth

Connect the e:cue Bridge8's Portective Earth to earth when
!
at least one connected cable runs outdoors.
Grounding of the e:cue Bridge8
Use Protective Earth where
applicable.
Ground the DMX connection
cable and the Ethernet cable.
Ground each cable separately.
18

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis