Herunterladen Inhalt Inhalt Diese Seite drucken

Personal Protective Equipment; Product Description; Identification; General Description - HEYLO DS 65 T Betriebsanleitung

Ölheizgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

– Protect the device against unauthorised interfer-
ence.
– Dirt, rain and snow can be sucked in by the fan.
Prevent this by adequate protection.
Safety clearances
The following minimum distances apply in the instal-
lation room:
Side panels to combustible objects 60 cm
Outlet side to combustible objects
Intake side
At the top
See also
 Technical data and factory settings
13.5

Personal protective equipment

Personal protective equipment serves to protect staff
against any hazards that could affect their safety or
health at work.
The following personal protective equipment must
be worn during transport and installation:
– Protective gloves to prevent injury to hands from
crushing
– Safety footwear to prevent injury from impact or
tripping
During cleaning and maintenance, the following
must be worn:
– Respiratory protection to prevent inhalation of
soot particles and dust
14

Product description

The device is a compact and portable unit that pro-
duces hot air. It is particularly suitable for the heating
of well-ventilated rooms and outdoor spaces (e.g.
warehouses, workshops, construction sites).
14.1

Identification

The device is clearly identified by means of the type
plate on the rear of the device.
EN
Type plates
Warmlufterzeuger
DS 65 T
230 V ~ 50 Hz
Art.-Nr.: 2202604
S.Nr.:
Technische Daten:
Anschlußwert
Stromaufnahme
Schutzart
Luftleistung
200 cm
Tankinhalt
Fig. 20: Type plate on device
60 cm
The type plate contains the following information:
300 cm
– Model
– Type number
– Electrical connection data
[
39]
– Serial number
14.2
The device is a compact and portable unit that pro-
duces hot air.
The device must only be operated:
– for the purpose for which it is intended
– in compliance with the safety instructions in
Design and scope of delivery
11
10
9
8
7
Fig. 21: Device design
11 Outlet for hot air
HEYLO GmbH
Im Finigen 9
D-28832 Achim
www.heylo.de
Tel.: +49 (0) 42 02 – 97 55 0
Fax: +49 (0) 42 02 – 97 55 97
0,8 KW
Nennwärmebelastung 65 KW
3,5 A
Nennwärmeleistung
IP 44
Brennstoff
3000 m³/h
Ölverbrauch max.
65 l

General description

chapter Safety
[
24]
1 Housing with com-
bustion chamber
and fan
3 Air inlet
5 Oil filter
7 Base
9 Control panel
10 Power cord holder
and exhaust gases
Oil heater DS 65 T
65 KW
Heizöl EL
5,3 kg/h
1
2
3
4
5
6
2 Handle
4 Oil pump
6 Fuel tank cap
8 Transport wheel
27 / 40

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

2202604