Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly: Electrical Connection | Teaching In The End Positions - Nice elero MVEF 14-R Serie Betriebs- Und Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Assembly: electrical connection | Teaching in the end positions

5.3
Connection example: MVEFx-14-R 230V / 50Hz
M
1~
Junction box
Shutter switch
oder -taster
or -button
Mains
Netz
230 V/50 Hz
230V/50Hz
PE
PE
N
N
L
L
Fig. 5 MVEFx-14-R 230V / 50Hz circuit diagram
Important
The motor controls in the up/down direction must be locked
against each other.
M
1~
A reversing delay of at least 0.5 seconds must be ensured.
5.4
Parallel circuit
Important
Several MVEFx-14-R cannot be connected in parallel.
Only single actuation is permitted.
boiter de
If several drives are to be connected to one connection,
a suitable sequencing relay must be used.
5.5
Commissioning
de volet
Important
reseau electrique
The drive is in commissioning mode when delivered.
230V/50Hz
PE
5.5.1 Automatic teaching of end positions
N
L
►The end positions are normally taught automatically taking
the prerequisites described in section 4 (product descrip-
tion) (self-teaching, without any elero assembly cable)
into consideration.
Automatic teaching of end positions
1
Connect the electric power in accordance with
section 5.2.
2
Check for functioning: If necessary, change or swap
the assignment of the direction buttons for the operat-
ing switch/push button.
The drive switches off automatically when the (upper or
lower) limit stop is reached.
The teaching process is completed due to subsequent
travel of the shutter.
5.5.2 Deletion of end positions
►Connection of the elero assembly cable is permitted only
to delete the end positions. Deleting the end positions
restores the delivery condition (factory setting).
6 | EN
junction box
1 0 2
power grid
230V/50Hz
PE
N
L
scatola di
derivatione
1 0 2
rete
230V/50Hz
PE
N
L
© elero GmbH
M
1~
Fig. 6 Connection for assembly cable
It is not possible to change or delete individual end posi-
tions. This is always done simultaneously for the upper and
lower end position.
1 0 2
Changing/deleting the end positions
1
Connecting drive via elero assembly cables.
2
Move the blind to a middle position.
3
Press the [UP▲] and [DOWN ▼] buttons simulta-
neously for 3 to 6 seconds. A low humming noise is
audible.
4
Press the direction button [UP ▲] or [DOWN ▼]: The
drive moves off, stops briefly and continues to move
M
as long as a travel button is pressed.
1~
The deletion of the end positions is finished.
5.6
Technical data
A summary of the most important technical parameters can
be found in the separately available "Technical Data Sheet".
6
Troubleshooting
Problem / Error
Possible cause
1 0 2
• End positions
• Drive already
cannot be
taught in to
the drive
• Drive stops af-
• Blind difficult to
ter short travel
• Drive is under-
• Drive does
• No power
not react
• Thermostat
• The drive runs
• Faulty
in only one
direction
Fig. 7 MVEFx-14-R troubleshooting
7
Servicing
The drive MVEFx-14-R is maintenance free.
Remedial ac-
tion
• Move the blind
has pro-
to the central
grammed end
position and
positions
set the drive
to its delivery
condition by
deleting the
end positions
• Check the
Blue (neutral conductor) (1)
Black (2)
move
smooth running
Brown (3)
of the blind and
Green-yellow
the selection of
sized
the drive
• Check mains
supply
voltage
• Allow drive to
has triggered
cool down
• Check
connection
connection

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis