Filling with Oil:
Pour the oil in through the filler neck on top of the main unit. The oil level must be checked with a
dipstick or a sight glass (see Fig. 27).
When doing this the dipstick must be screwed into the lowest position otherwise the reading will not
be accurate (see Fig. 28).
Oil dipstick
Fig.27
When topping up ensure that no loose nuts, bolts, gaskets, dust, water or other foreign objects fall into
the unit.
If the oil level is below the minimum level adequate lubrication cannot be guaranteed.
If the oil level is above the maximum level the quality of the oil will deteriorate more quickly because of
the high oil temperature.
Use the drain outlet underneath the unit to drain the oil. The oil should still be hot at this time. If the
unit has a breathing filter, open it to make it easier to drain and top up the oil.