Page EN-6
Safety
■ Failure to install mounting screws or
fasteners contrary to this instruction
may cause electrical hazards.
■ If a glass cover is broken, the exhaust
hood must not be used until the glass
cover has been replaced. If this is the
case, contact our Service department
(see page EN-21).
CAUTION
Risk of injury!
■ When mounting, please note that
some parts may have sharp edges.
■ Use a stable stepladder to mount.
■ Only use mounting materials that
are suitable for the characteristics of
the ceiling and walls. When in doubt,
consult an expert.
Risk of burns!
■ Touchable parts may become hot if
used with cooking appliances.
Fire hazard!
■ The distance between the cooking
surfaces and the lower edge of the
hood must be at least 65 cm for gas
cookers.
■ For gas stovetops, you must read the
user manual for the stovetop! If the
manual stipulates a larger distance,
this must be observed.
■ Do not fl ambé foods under the
exhaust hood!
■ Only deep-fry foods under the exhaust
hood under constant supervision.
■ Keep the exhaust hood clean. Grease
build-ups can ignite when heated to
high temperatures.
■ Clean the exhaust hood according to
the instructions!
Risks during exhaust air operation
WARNING
Risk of suffocation/explosion!
The air in the room where the exhaust
hood is operating is extracted by fan
and released outside. If, in this room, a
fi replace requiring indoor air – such as a
gas fi re or other fuel-based heating sys-
tem – is also in use, the oxygen that is
necessary for combustion may also be
extracted. This can result in the fl ame
being extinguished and gas being re-
leased or the room becoming saturated
with exhaust fumes.
■ It is possible to run the appliance wi-
thout any risk by, for example, provi-
ding non-sealable openings in doors,
windows or ventilation conduits th-
rough which the combustion air can
escape, and by achieving a negative
pressure level in the installation spa-
ce of maximum 0.04 mbar. This pre-
vents the exhaust fumes from being
sucked back into the room.
■ In order to determine the necessary
measures, the entire ventilation sys-
tem throughout the home must be
reviewed. Consult the gas safety
consultant who is responsible for the
home.
■ Never attach the exhaust hood to a
ventilation shaft, chimney or smo-
kestack! The air being extracted must
not travel through a channel in which
warm air circulates. The extracted air
may only be released to the outside
through a separate air channel inten-
ded exclusively for the exhaust hood.