Function and features

Switching mode
Binary mode
All manuals and user guides at all-guides.com
• The sensor detects the level of media in vessels within the active
zone,
• shows the current level on its display
• and generates 2 output signals according to the set output con-
figuration.
Two evaluation modes are available:
Sensor with 4 different outputs to be configured.
Switching function
(can be selected for each
output separately)
16-step analog evaluation with a resolution of 6.25 % of the measur-
ing range.
OFS
The outputs OUT1...OUT4 provide a 4-digit value in the 8-4-2-1 bina-
ry code for each step (table of values → page 28).
output 1
output 2
hysteresis function / N.O. (Hno)
hysteresis function / N.C. (Hnc)
window function / N.O. (Fno)
window function / N.C. (Fnc)
L
1
OUT1
0
1
OUT2
0
1
OUT3
0
1
OUT4
0
output 3
output 4
t