Herunterladen Inhalt Inhalt Diese Seite drucken

Technische Daten Pem-008A - RCS PRO-LINE PSS-224A Bedienungsanleitung

Inhaltsverzeichnis

Werbung

PEM-008
MICROPHONE ExTENSION UNIT
6. Align connecting metals and tighten screws
7. unscrew the left side part of the substation
8. Disassemble the left part of the sheet metal angles of the
substation
9. Hang up the PEM-008A into the substation
10. align the appliance components and tighten screws
moderately
11. Attach the dismantled side angles on the left side of the
PEM-008A again
12. Align angles and tighten screws moderately
13. Screw the plastic side frame again
14. Affix the internal bus cable PFK-100 (see chapter „cable
PFK-100")
15. Screw base plate combination again
Picture shows:
Laying of the
ribbon cable PFK-100
TECHNICAL DATA PEM-008A
Power supply via ribbon cable PFK-100
Nominal current min./max.
Possible internal addresses
Illuminated group buttons
Dimensions (wxhxd)
Weight
All manuals and user guides at all-guides.com
5V
150 µA / 5 mA
1 - 7
8
182 x 55 x 45 mm
330 g
6. Verbindungsbleche ausrichten und Schrauben anziehen
7. linkes Seitenteil der Sprechstelle abschrauben
8. linken Blechwinkel von der Sprechstelle demontieren
9. PEM-008A in die Sprechstelle einhängen
10. Gerätekomponenten ausrichten und Schrauben maßvoll
anziehen
11. demontierten Seitenwinkel wieder an die linke Seite des
PEM-008A anlegen
12. Winkel ausrichten und Schrauben maßvoll anziehen
13. Kunststoff-Seitenteil wieder anschrauben
14. internes Buskabel PFK-100 anstecken (siehe Abschnitt
„Kabel PFK-100")
15. Bodenplattenkombination wieder anschrauben
Abbildung zeigt:
Verlegung des
Flachbandkabels PFK-100

TECHNISCHE DATEN PEM-008A

Stromversorgung über Anschlusskabel PFK-100 5V
Stromaufnahme min./max. Dauerstrom
Mögliche interne Adressen
Beleuchtete Speichertasten
Länge x Breite x Höhe
Gewicht
150 µA / 5 mA
1 - 7
8
182 x 55 x 45 mm
330 g