MOUNTING OF THE ACTUATORS
After having set on the pillars the measures chosen from the
table of the previous page, go ahead and proceed with the
following operations:
1. Set and fasten the brackets on the pillars and the gate.
ATTENTION: the front bracket must be positioned
54 mm lower than the rear bracket.
2. Close the shutter.
3. Unblock the actuators.
4. Take apart the two plastic covers (1 and 2)
5. Position AXIL on the brackets and fasten bolt 3 with the
corresponding self-locking nut and two washers
ATTENTION: Insert the two washers as indicated in
panel A.
6. Fasten bolt 4 after having inserted the washer.
ATTENTION: verify that it is in draw-bar bubble as
indicated in panel B
7. Try to open and close the shutters manually several times
making sure that there are not frictions between the actuator
and the structure of the gate.