Location
The machine should be kept away from flammable and explosive materials, as well as from sunlight and
intense light. The machine should be placed in a well-ventilated location.
The machine must be set up on sufficiently firm ground, if necessary, according to the minimum
requirements of the information given in the foundation plan.
In addition to the ground conditions, the guidelines and instructions of the accident prevention regulations
as well as the workplace regulations must be observed when selecting an installation site.
Based on a torn double steel-proven concrete slab made of C25 / 30 and should have a
minimum thickness of 200 mm.
Max. Slope of 4 m
Concrete drying time:
The operator is liable for the structural specifications and must ensure that the
specifications and static requirements for installing the lift are guaranteed.
When installing on floor ceilings, their sufficient load-bearing capacity must be checked. In general, it is
advisable to consult a building expert for an assessment when installing on floor ceilings.
Distance between the column and the wall
Permissible room temperatures:
Maximum permissible humidity:
Above sea level:
The mains connection and earthing cable (see technical data) must have a plug connection (socket and
plug).
Necessary electr. Connections and supply lines
The machine is only to be installed and used in closed rooms. It does not have any corresponding safety
features (e.g. IP protection, galvanized design, etc.).
The lift is only designed for installation in dry rooms. Installation in wet rooms and
rooms at risk of explosion is not permitted.
® Urheberrecht ATH-Heinl GmbH & CO.KG, Alle Rechte vorbehalten / Druckfehler und technische Änderungen vorbehalten / Stand: 2021-08
13mm
Min. 20 Days
See tech. data and may only be made by a
specialist
Produkthersteller ATH-Heinl GmbH & CO.KG
- 11 -
Min. 800 mm
Min. 3200mm
-10/+50 °C
≤80% at 30 °C
≤2000m