Function check output /programming input
(FC-OUT/CAL, pin 2)
This is a bidirectional wire.
• When used as function check output, output signals of the unit can
be evaluated
• When used as programming input, operations can be performed
(see Operation).
Signals on the function check output
Status
Function check
Adjustment error
When used as programming input:
Type of unit
p-switching (type FPKG)
n-switching (type FNKG)

Operation

Adjust the sensor. To do so, press
the programming pushbutton with
a blunt object.
You can also operate the unit via
the programming input "CAL" (sig-
nal duration = duration of the press
of the pushbutton).
All manuals and user guides at all-guides.com
Signal
The function check output is enabled
The function check output changes bet-
ween enabled and disabled state at 8Hz
Performing an operation
To activate the function the programming
wire is electrically connected to the wire
"L+"
To activate the function the programming
wire is electrically connected to the wire
"L-"