Full adjustment
After empty adjustment the full state is to be achieved, if possible, so
that the unit switches.
5 ... 10 s
The full adjustment can be repeated as often as you like. The stored
value for the empty state is not overwritten by the full adjustment.
After a new empty adjustment both values are automatically set again,
the values last defined are overwritten.
Therefore always carry out the empty adjustment first, then, if
necessary, the full adjustment!
Locking
The stored adjustment values can be protected against unauthorised
programming as follows (factory setting: not locked):
min. 10 s
When the programming pushbutton is released the unit is locked and
all programming functions are inactive. The unit returns to the opera-
ting mode.
If this operation starts from the locked state, the green LED goes out
briefly but then does not react any more.
All manuals and user guides at all-guides.com
Press the programming pushbutton until the
green LED flashes quickly
(= unit in the adjustment mode).
The LED first flashes slowly (about 1 Hz), after 5s
it flashes double as quickly (about 2 Hz).
After adjustment the green LED lights
continuously. For the output function
"NO" the yellow LED lights additionally
(= unit is in the operating mode).
Press the programming pushbutton for min. 10s.
The green LED first flashes slowly (about 1Hz),
after 5s more quickly (about 2Hz), after 10s it
goes out, the unit is locked.