DIGITAL DISPLAY
On-screen display
Meaning
FL
> The water tank is full.
E1
> The humidity sensor detects an anomaly.
E2
> The ambient temperature sensor detects an anomaly.
P1
> The appliance is defrosting.
CL
> The appliance is currently undergoing inside drying.
> The [ Child security ] is engaged and other control buttons
LC
are locked.
MAINTENANCE
• Make sure that the appliance is off and unplug before performing any work.
• Do not immerse the appliance in water or in any other liquid.
• Do not use corrosive, abrasive or flammable products to clean the appliance.
CLEANING THE REMOVABLE FILTER: The removable filter captures dust and extends the appliance
efficiency. It is recommended to clean it every month. Pull the handle of the removable filter,
clean it with warm water and a soft brush then dry it and reposition it.
Be careful not to dry the filter in direct sunlight or near a strong heat source.
CLEANING THE APPLIANCE: Use a soft cloth to remove dust at the air inlets and outlets.
CLEANING THE TANK: Remove the tank from the appliance and unclip the handle and then the
lid. To avoid calc deposit, clean the tank at least once a month with an appropriate product
or with white vinegar.
STORAGE  OF  THE  APPLIANCE:  To avoid any bacteria or virus proliferation, never store the
appliance with water inside the tank and be sure that the appliance is perfectly dry.
1. Empty and clean the tank.
2. Clean the air inlets and outlets as well as the removable filter.
3. Once the different parts have dried properly, store the product in a place that is protected
against dust and that is clean, dry and ventilated.
24
FAQ
Problem
Reason
> The product is not correctly
plug or there is an electrical
problem.
> There is a problem on the
The appliance
electrical system of your
does not work
house.
> The tank is full.
> The tank is not properly
placed.
> The removable filter is dirty
what obstructs the air flow.
> The air inlet or outlet is
Drop in the
obstructed by something.
appliance
performance
(less water in
the tank)
> Temperature is too low.
> Humidity rate is already low.
> Something obstructs the fan.
> The product has a
functioning problem.
Abnormal noise
> The appliance makes a kind
of whisper.
> The appliance is tilted or not
properly secured.
> The connection between
the appliance and
Leakage
the drainage hose has
loosened.
> The drainage hose is bent,
twisted or obstructed.
The appliance
> Air filter is obstructed.
does not
produce air
> In order to extract air from
The air coming
the room, the dehumidifier
out of the
compressor slightly heats
appliance is hot
the air.
Solution
> Plug the socket correctly and
check the voltage and the good
functioning of your electrical
system.
> Empty the tank.
> Push and place the tank properly.
> Clean the removable filter.
> Leave at least 50cm behind,
around and in front of the
appliance.
> Below 5°C the product works in
Defrost Mode. It cannot therefore
dehumidify to a maximum of its
capacity.
> Make sure that no object obstructs
the air flow.
> Contact your reseller for service
support.
> This is the sound produced by the
refrigerant gas. This is a normal
phenomenon.
> Place the appliance on a flat
surface before the switching on.
> Correctly attach the drainage
hose.
> Remove obstructing elements and
straighten the hose up.
> Please see "Maintenance"
paragraph.
> This is a normal phenomenon.