Vario RC-Modul Bedienungsanleitung Seite 21

Intelligente poolsteuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.5.
Controlling the VA SALT SMART saltwater chlorinator
Press the " " button to wake the RC module from sleeping mode,
1.
In the default RC screen, press the "<>" button to switch to the chlorinator control screen.
2.
If there is no chlorinator unit correctly connected, the SW chlorinator control menu will not
appear !!!
Note:
The saltwater chlorinator unit can signalize the operating mode and also alarms/notifications. In case of an alarm, the alarm can
be reset only on the chlorinator unit – not via VArio – by pressing the "OK" button.
3.
You may configure certain operating parameters of a connected chlorinator form your RC module. The
logic of the chlorinator menu is the same as that of DIN module. Press the "V" button to enter the
chlorinator unit main configuration
Setpoint pH
>Setpoint RX
Max. power
(%)
Cell voltage
(V)
Salinity
>Warnings
Alarms
Operation mode
Pasmo alarmu PH
The "Setpoint PH" menu allows the user to change pH settings of the chlorinator
4.
Setpoint pH
>
7.2
Note:
You may adjust the value of the RX parameter exactly the same way. Cancel any unwanted changes by pressing the "ENT/ESC" button.
The default code for parameter changes is "1234". The code may be changed only by a pool professional with a service module. When a
wrong code is entered, changes will not be saved and the unit will return to its default screen.
The "Max. power" menu allows the user to limit the maximum output of the salinator cell (0-100%):
5.
Max. power (%)
80 %
Filtration
Dosing
Temp 22°C
Light.014
Att1 015
Att3 000
Att4 015
menu:
Press "V" button to move down in the menu,
a.
Press "ꓥ" button to move up in the menu,
b.
The ">" arrow indicates the selected parameter,
c.
Press the "ENT/ESC" key to enter the selected parameter menu.
d.
Flashing orange rectangle on the display indicates ongoing information
transfer between the DIN/RC modules and the dosing unit – wait for the
communication to finish in order to change the parameter setting.
Select ">Setpoint PH" and press "ENT/ESC" button,
a)
Press "SET/SEND" to activate pH setting mode,
b)
Press "V" to decrease pH value (1 click = -0,1 pH),
c)
Press "ꓥ" to increase pH value (1 click = +0,1 pH),
d)
Press "SET/SEND" to confirm and send changes to DIN module,
e)
An "OK" message will appear at the bottom right of the display.
f)
Select ">Max. power" and confirm with "ENT/ESC",
a)
Press "SET/SEND" to activate value adjustment,
b)
Press "V" to lower power (-1 % / 1x click),
c)
Press "ꓥ" to increase power (+1 % / 1x click),
d)
Press "SET/SEND" to confirm and send changes to DIN
e)
An "OK" message will appear at the bottom right of the
f)
[ ON]
PH=7.1
[ ON]
RX=610mV
"<>"
[ ON]
Power
Mode
[≤7.2]
[≥700]
25%
Automatic
unit:
module,
display.
9