schmalz FXP-i Betriebsanleitung Seite 92

Flächensauggreifer
Vorschau ausblenden Andere Handbücher für FXP-i:
Inhaltsverzeichnis

Werbung

Anhang
143
0x008F
0
ct1
144
0x0090
0
ct2
145
0x0091
0
ct3
 Diagnosis

Device Status
32
0x0020
0
36
0x0024
0
37
0x0025
0
130
0x0082
0
138
0x008A
1
138
0x008A
2
139
0x008B
0

Condition Monitoring [CM]
146
0x0092
0

Energy Monitoring [EM]
155
0x009B
0
156
0x009C
0
157
0x009D
0
92 / 94
counter
Erasable
vacuum-on
4 bytes
counter
Erasable valve
operating
4 bytes
counter
Erasable
condition
4 bytes
monitoring
counter
Error Count
2 bytes
IO-Link Device
1 byte
Status
Detailed Device
96 bytes
Status
Active Errors
2 bytes
Extended
Device Status -
1 byte
Type
Extended
Device Status -
2 bytes
ID
NFC Status
1 byte
Condition
2 bytes
monitoring
Air consumption
per cycle in
1 byte
percent
Air consumption
2 bytes
per cycle
Energy
2 bytes
consumption
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
Can be reset by System
Command "Reset erasable
counters" (stored every 1000
counts)
Can be reset by System
Command "Reset erasable
counters" (stored every 1000
counts)
Can be reset by System
Command "Reset erasable
counters" (stored every 1000
counts)
Number of errors since last
power-up
0 = Device is operating properly
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
Information about currently
pending events
Fixed-length array format
according to IO-Link
specification V1.1
Bit 00: Internal error: data
corruption (E01)
Bit 01: reserved
Bit 02: Primary voltage too low
(E07)
Bit 03: Primary voltage too high
(E17)
Bit 04-07: reserved
Bit 08: short circuit at OUT2
(E12)
Bit 09-10: reserved
Bit 11: Measurement range
overrun (FFF)
Bit 12-14: reserved
Bit 15: IO-Link communication
interruption (E08)
Type code of active device
status (see below)
ID code of active device status
(see below, corresponds to IO-
Link events)
Result of recent NFC activity:
0x00: Data valid, write finished
successfully
0x23: Write failed: Write access
locked
0x30: Write failed: parameter(s)
out of range
0x31: Write failed: parameter
value too high
0x32: Write failed: parameter
value too low
0x41: Write failed: parameter set
inconsistent
0xA1: Write failed :invalid
authorisation
0xA2: NFC not available
0xA3: Write failed: invalid data
structure
0xA5: Write pending
0xA6: NFC internal error
Bit 0: Valve protection active
Bit 1: Evacuation time t1 above
limit [t-1]
Bit 2: Leakage rate above limit [-
L-]
Bit 3: SP1 not reached in
suction cycle
Bit 4: Free-flow vacuum > rP2
but < SP1
Bit 5: Primary voltage US outside
of optimal range
Bit 6: reserved
Bit 7: reserved
Bit 8: Input pressure outside of
operating range
Bit 9-15: reserved
Air consumption of last suction
cycle (unit: 1 %)
Air consumption of last suction
cycle (unit: 0.1 Nl)
Energy consumption of last
suction cycle (unit: 1 Ws)
DE
· 30.30.01.02851 · 00 · 06/21