Herunterladen Inhalt Inhalt Diese Seite drucken

Drawer Leds - Dell EMC PowerVault ME484 JBOD Bereitstellungshandbuch

Speichergehäuse
Vorschau ausblenden Andere Handbücher für EMC PowerVault ME484 JBOD:
Inhaltsverzeichnis

Werbung

2. Latch button (shown in the locked position)
3. Drive fault LED
Tabelle 4. Drawer LED descriptions
Fault LED (Amber)
Off
Off
Blinking: 1 s on/1 s off
Any links down: On
On
Off
Off
Off
Off
Blinking: 3 s on/1 s off
Off
Blinking: 3 s on/1 s off
Off
Off
*If multiple conditions occur simultaneously, the LED behaves according to the conditions that are listed in this table. The LED states
occur in the order that is displayed in the table from top to bottom.
Each DDIC has a single Drive Fault LED. A disk drive fault is indicated when the Drive Fault LED is lit amber. In the event of a disk drive
failure, follow the procedure in the ME484 JBOD Storage System Owner's Manual to replace the DDIC.
Identifier
Version
Status

Drawer LEDs

See the ME484 JBOD Storage System Owner's Manual for a visual description of the LEDs on each drawer bezel.
Tabelle 5. Drawer LED descriptions
LED
Status/description
Sideplane
Green if the sideplane card is working and there are no power problems.
OK/Power
Good
Drawer Fault
Amber if a drawer component has failed. If the failed component is a disk, the LED on the failed DDIC lights amber.
Follow the procedure in the ME484 JBOD Storage System Owner's Manual to replace the DDIC. If the disks are OK,
contact your service provider to identify the cause of the failure, and resolve the problem.
Logical Fault
Amber (solid) indicates a disk fault. Amber (blinking) indicates that one or more storage systems are in an impacted
state.
Cable Fault
Amber indicates the cabling between the drawer and the back of the enclosure has failed. Contact your service provider
to resolve the problem.
Activity Bar
Displays the amount of data I/O from zero segments lit (no I/O) to all six segments lit (maximum I/O).
Graph
Status/description*
Off (disk module/enclosure)
Not present
Identify
Drive link (PHY lane) down
Fault (leftover/failed/locked-out)
Available
Storage system: Initializing
Storage system: Fault-tolerant
Storage system: Degraded (non-critical)
Storage system: Degraded (critical)
Storage system: Quarantined
Storage system: Offline (dequarantined)
Storage system: Reconstruction
Processing I/O (whether from host or internal activity)
GUID-1F45BEAC-B20B-4084-9547-0FEA8EA98C00
3
In translation
LEDs
17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis