Herunterladen Inhalt Inhalt Diese Seite drucken

Cameo ZENIT W600 SMD Bedienungsanleitung Seite 21

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
Dimmer
= Dimmer curve
Curve
Power
= Operating mode
Mode
Dimmer
= Dimmer response
response
Color Ca-
= Color calibration
libration
Autolock
= Automatic locking of
the controls
PWM
= LED PWM frequency 800 Hz / 1200
Frequ-
ency
Fan
= Adjust fan control
Linear
Light intensity increases linearly with
DMX value
Exponential
Light intensity can be finely adjusted at
lower DMX values and broadly adjusted at
higher DMX values
Logarithmic
Light intensity can be broadly adjusted at
lower DMX values and finely adjusted at
higher DMX values
S-curve
Light intensity can be finely adjusted at
lower and higher DMX values and broadly
adjusted at medium DMX values
Normal
Constant brightness
Boost
Brief maximum brightness (Blinder func-
tion, approx. 3 seconds)
LED
Light responds abruptly to changes in
DMX value
Halogen
Light behaves like a halogen spotlight
with slight brightness changes
RAW
R, G, B and W with maximum value 255
User Calibra-
Individual color calibration. Cross-mode
tion
brightness setting of R, G, B, A and L with
values from 000 - 255.
Factory Cali-
Factory calibration of R, G, B and W
bration
(across all modes)
Smart Calibra-
Merging factory and RAW calibration
tion
On
Automatic locking of the controls after
approximately 1 minute of inactivity.
After attempted input the display shows:
"Locked!"
Unlock: press and hold UP and DOWN
simultaneously for approx. 5 seconds
Off
Automatic locking of the controls is
disabled
Configuration of LED PWM frequency
Hz / 2000 Hz /
3600 Hz / 12
kHz / 25 kHz
Auto Fan
Automatic fan speed control
Silent Fan
Constant fan speed with adjusted bright-
ness
Off
Disabled fans at adjusted brightness
21

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Clzw600smd

Inhaltsverzeichnis