Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Cleaning Encoder; Changing Blanking Plug (If Fitted) - Lenord+Bauer GEL 27-Serie Betriebsanleitung

Drehgeber mit bis zu 8 kanälen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Lenord + Bauer
8

Maintenance

The encoder does not contain any parts in need of maintenance. Do not try to repair
the encoder yourself. Any repairs necessary are only allowed to be undertaken by LE-
NORD + BAUER or a specifically authorised representative.
When?
What?
Encoder faulty
Regularly
As required
8.1

Cleaning encoder

To avoid damage to the encoder, please pay attention to the following:
– Do not use a high pressure cleaner.
– If the connection has been disconnected, prevent water, dirt or other substances
entering the open parts.
 Clean the encoder with water or a non-corrosive cleaning agent.
8.2

Changing blanking plug (if fitted)

On encoder designs with a blanking plug, the blanking plug may come loose due to
vibration. To ensure adequate sealing, a blanking plug that has come loose must be
replaced.
 Remove and dispose of the blanking plug.
 Clean the cover and the thread in the bore using acetone.
Ensure no foreign bodies fall through the hole into the housing.
 Prior to screwing in, clean the new blanking plug and lock the thread using Loctite
243.
 Tighten the blanking plug to maximum 5 Nm.
GEL 27xx
Cleaning encoder
Replace the encoder.
Check the encoder for damage.
Clean the encoder (see
Grease the shaft on the encoder, if it is removed during an inspec-
tion.
Replace the mating connector (not included in the scope of sup-
ply). Take into account that you will need to shorten the connection
cable during this process.
Change the blanking plug (see
→ page
49).
→ page
49).
8 Maintenance
49