1. GENERAL

This booklet briefly outlines where and how to install the air
conditioning system. Please read over the entire set of instructions
for the indoor and outdoor units and make sure all accessory parts
listed are with the system before beginning.
That the installation of pipe-work shall be kept to a minimum.
This symbol shows that this equipment uses
a flammable refrigerant. If the refrigerant is
WARNING
leaked, together with an external ignition
source, there is a possibility of ignition.
This symbol shows that the Operating
CAUTION
Instructions should be read carefully.
This symbol shows that a service personnel
CAUTION
should be handling this equipment with
reference to the Technical Manual.
This symbol shows that there is information
CAUTION
included in the Operating Instructions and/or
Installation Instructions.

1-1. Tools Required for Installation (not supplied)

1. Flathead screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Carpenter's level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits
9. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for deburring)

1-2. Accessories Supplied with Unit

See Table 1-1.
Table
Type
1-1
Ducted

1-3. Type of Copper Tube and Insulation Material

If you wish to purchase these materials separately from a local
source, you will need:
1.
Deoxidized annealed copper tube for refrigerant tubing.
2.
Foamed polyethylene insulation for copper tubes as required to
precise length of tubing. Wall thickness of the insulation should
be not less than 8 mm.
3.
Use insulated copper wire for fi eld wiring. Wire size varies with
the total length of wiring. Refer to 4. ELECTRICAL WIRING for
details.
CAUTION
Check local electrical codes and regulations before obtaining
wire. Also, check any specified instructions or limitations.

1-4. Additional Materials Required for Installation

1.
Refrigeration (armored) tape
2.
Insulated staples or clamps for connecting wire (See your local
codes.)
3.
Putty
4.
Refrigeration tubing lubricant
5.
Clamps or saddles to secure refrigerant tubing
6.
Scale for weighing
Table 1-1 (Ducted)
Part Name
Figure
Washer
Flare insulator
Hose band
Foam drain
socket
Drain hose
Flange
Screw
Use M10 for suspension bolts.
Suspension bolts and nuts are fi eld supply.
6
Q'ty
Remarks
For suspending indoor unit
8
from ceiling
2
For gas and liquid tubes
5
For securing drain hose
For drain hole
1
(another side of drain hose)
1
2
For inlet duct installation
4