Herunterladen Inhalt Inhalt Diese Seite drucken
Panasonic S-36PU2E5B Bedienungsanleitung
Vorschau ausblenden Andere Handbücher für S-36PU2E5B:

Werbung

4-Way Cassette
Model No.
INDOOR UNIT
4-Way Cassette
(Type U2)
S-36PU2E5B
S-71PU2E5B
S-45PU2E5B
S-100PU2E5B
S-50PU2E5B
S-125PU2E5B
S-60PU2E5B
S-140PU2E5B
OUTDOOR UNIT
Single Split
See the page 82.
ENGLISH
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
(Type U2)
FRANÇAIS
Avant d'utiliser l'appareil, lisez ce mode d'emploi dans son intégralité et
conservez-le pour toute référence ultérieure.
ESPAÑOL
Antes de operar la unidad, lea atentamente estas instrucciones de
funcionamiento y guárdelas para futuras consultas.
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die
künftige Verwendung auf.
ITALIANO
Prima di utilizzare l'unità, leggere a fondo queste istruzioni per l'uso e
conservarle come riferimento futuro.
NEDERLANDS
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en
bewaar ze voor toekomstig gebruik.
PORTUGUÊS
Antes de utilizar o aparelho, leia completamente este manual de instruções
e guarde-o para futuras referências.
EΛΛΗΝΙΚΆ
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες
χρήσης και διατηρήστε τις για μελλοντική αναφορά.
БЪЛГАРСКИ
Преди да започнете експлоатация на този уред, прочетете внимателно
тези инструкции и ги запазете, за да можете да правите справки с тях и
в бъдеще.
TÜRKÇE
Üniteyi çalıştırmadan önce bu çalıştırma talimatlarını iyice okuyun ve
gelecekte başvurmak için saklayın.
Operating Instructions
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
Air Conditioner
2 ~ 9
E
10 ~ 17
F
18 ~ 25
E
26 ~ 33
D
34 ~ 41
I
42 ~ 49
N
50 ~ 57
P
58 ~ 65
E
66 ~ 73
Б
74 ~ 81
T
ACXF55-19091
NGLISH
RANÇAIS
SPAÑOL
EUTSCH
TALIANO
EDERLANDS
ORTUGUÊS
ΛΛΗΝΙΚΆ
ЪЛГАРСКИ
ÜRKÇE

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Panasonic S-36PU2E5B

  • Seite 1 Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et RANÇAIS INDOOR UNIT conservez-le pour toute référence ultérieure. 4-Way Cassette (Type U2) ESPAÑOL 18 ~ 25 S-36PU2E5B S-71PU2E5B Antes de operar la unidad, lea atentamente estas instrucciones de SPAÑOL S-45PU2E5B S-100PU2E5B funcionamiento y guárdelas para futuras consultas. S-50PU2E5B...
  • Seite 2: Inhaltsverzeichnis

    Safety Precautions Thank you for purchasing this Panasonic product. This product is a commercial air conditioner indoor unit. Installation Instructions attached. Contents The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or...
  • Seite 3 WARNING If the refrigerant comes in contact Do not use modified with a flame, it produces a toxic cord, joint cord, gas. extension cord or unspecified cord to prevent For safety, be sure to turn the overheating and fire. air conditioner off and also to disconnect the power before cleaning or servicing.
  • Seite 4 WARNING CAUTION This appliance is intended to be used by The appliance shall be stored expert or trained users in shops, in light in a room without continuously industry and on farms, or for commercial operating open flames (for use by lay persons. example: an operating gas This appliance is not intended for use appliance) and ignition sources...
  • Seite 5: Precautions For Use

    Precautions for Use Installation Information for Users on Collection and Disposal of Old Equipment and Used Batteries This air conditioner must be installed properly by qualified installation technicians in accordance with the Installation hese symbols on the products, packaging, Instructions provided with the unit. and/or accompanying documents mean that Before installation, check that the voltage of the electric used electrical and electronic products and...
  • Seite 6: Names Of Parts

    Names of Parts INDOOR UNIT Label Type U2 Water drain (attached to the lid of electrical component box) Air intake grille This air conditioner incorporates a biocidal product. Ceiling panel (air intake) (optional) Ionized air generated by a device incorporated in the air conditioner deactivates bacteria and viruses in the air, and on surfaces, and inhibits Air outlet...
  • Seite 7: Maintenance

    Maintenance Indoor unit WARNING (e.g. Type U2) Air outlet For safety, be sure to turn the air conditioner off and disconnect the power before cleaning. (Otherwise, electric shock or injury may result because the fan is rotating at high speed.) Air intake Do not pour water on the indoor unit.
  • Seite 8: Troubleshooting

    Troubleshooting Check before consulting or requesting services. Symptom Cause / Action Sound like streaming water is heard • Sound of refrigerant liquid flowing inside unit during operation or after operation. • Sound of drainage water through drain pipe Noise Cracking noise is heard during operation •...
  • Seite 9: Before Requesting Services

    Before Requesting Services Symptom Cause Action The air Power failure or after power failure Press the power ON/OFF button on the remote controller. conditioner does • If the breaker is turned off, turn the power on. not operate The operation (power) button is turned off. •...
  • Seite 10 Connectable outdoor unit lineup Europe „ Refrigerant type : R410A Outdoor unit type 1-phase U-36PE2E5A U-50PE2E5A U-60PE2E5A PE1,PE2 3-phase 1-phase U-60PEY2E5 PEY1,PEY2 3-phase Outdoor unit type 1-phase U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A PE1,PE2 3-phase U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A 1-phase U-71PEY2E5 U-100PEY1E5 U-125PEY1E5 PEY1,PEY2 3-phase...
  • Seite 11: Specifications

    Specifications Indoor unit 4-Way Cassette (Type U2) Model Name S-36PU2E5B S-45PU2E5B S-50PU2E5B S-60PU2E5B S-71PU2E5B S-100PU2E5B S-125PU2E5B S-140PU2E5B 220 - 230 - 240 V ~ 50 Hz Power source (Europe) 230 - 240 V ~ 50 Hz Power source (Oceania) –...
  • Seite 12: Outdoor Unit

    Specifications Outdoor unit Single Split Outdoor Unit (R410A) Model Name U-36PE2E5A U-50PE2E5A U-60PE2E5A Europe 220 - 230 - 240 V ~ 50 Hz Power source Cooling capacity 12,300 17,100 20,500 BTU/h Heating capacity 13,600 19,100 23,900 BTU/h Sound Pressure level 45 / 46 46 / 48 46 / 49...
  • Seite 13 Model Name U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A U-200PE2E8A U-250PE2E8A Europe 380 - 400 - 415 V 3N ~ 50 Hz Power source Model Name – U-100PE1R8A U-125PE1R8A U-140PE1R8A – – Oceania 400 - 415 V 3N ~ 50 Hz Power source 10.0 12.5 14.0...
  • Seite 14 Specifications Outdoor unit Single Split Outdoor Unit (R32) Model Name – – U-100PZ2E5 U-125PZ2E5 U-140PZ2E5 Europe Power source 220 - 230 - 240 V ~ 50 Hz Model Name U-60PZ2R5 U-71PZ2R5 U-100PZ2R5 U-125PZ2R5 U-140PZ2R5 Oceania 230 - 240 V ~ 50 Hz Power source Cooling capacity 20,500...
  • Seite 15: Corresponding Language Table

    Corresponding language table English Français Español Deutsch 4-Way Cassette (Type U2) Cassette 4 voies (Type U2) Cassette de 4 vías (Tipo U2) 4-Weg-Kassette (Typ U2) Single Split Bi-bloc simple Un solo split Einzel-Split English Italiano Nederlands Português 4-Way Cassette (Type U2) A cassetta a 4 vie (Tipo U2) 4-Weg cassette (Type U2) Cassete de 4 vias (Tipo U2)
  • Seite 16 Specifications Corresponding language table English Italiano Nederlands Português Model Name Modello Modelnaam Nome do modelo Power Source Fonte di alimentazione Voeding Fonte de alimentação Cooling Capacity Capacità di raffreddamento Koelingscapaciteit Capacidade de arrefecimento Sensible Sensibile Verstandig Sensível Latent Latente Latent Latente Heating Capacity Capacità...
  • Seite 17 English Values include the dimension and weight of an optional ceiling panel. Français Les valeurs comprennent les dimensions et le poids d’un plafonnier en option. Español Los valores incluyen las dimensiones y el peso de un panel de techo opcional. Die Werte schließen Abmessungen und Gewicht einer als Sonderausstattung erhältlichen Deutsch Deckenverkleidung mit ein.
  • Seite 18 MEMO...
  • Seite 19 MEMO...
  • Seite 20 Panasonic Corporation Authorised representative in EU Website: http://www.panasonic.com Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, Germany © Panasonic Corporation 2017 - 2018 ACXF55-19091 Printed in Malaysia DC1117-10218...

Inhaltsverzeichnis