Herunterladen Inhalt Inhalt Diese Seite drucken

Connection Of External Accessories And; Control Units - Vaillant atmoCRAFT VK 654/9 Installations- Und Wartungsanleitung

Vorschau ausblenden Andere Handbücher für atmoCRAFT VK 654/9:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5 Installation

5.4.5 Connection of external accessories and

control units

When connecting accessories, the existing bridge on the
relevant plug must be removed.
Take especial care that the bridge is removed when
incorporating an installation thermostat.
Controller
Connection
VRC 410s (1-circuit
Insert into the operating aperture
controller)
Operating component: Insert into the
VRC 420s (2-circuit
operating aperture mixer module:
controller)
electronic box ProE plug
auroMATIC 620
Terminal X1/7-8-9
calorMATIC 630
Terminal X1/7-8-9
VRT 40
Electronics box ProE plug
VRT 390
Terminal X1/7-8-9
VRT 320
Terminal X1/7-8-9
VRT 330
Terminal X1/7-8-9
Receiver Insert into the operating
VRT 340f
aperture
VR 30/2
Plug X6/telephone jack (next to X2)
VR 80
to eBUS of controller calorMATIC 630 or
VR 90
auroMATIC 620
Mixer module VR 60
Table 5.1 Overview of the controllers which can be used
Accessories and external installation components
External sensor VRC-DCF (from control set 410/420, see above)
Maximum thermostat
Control fume extraction hood and Control external gas solenoid
valve and Fault signal display and External heating pump and
Control circulation pump and Control of an external exhaust gas
diverter
Control of external solenoid valve or Operating and fault signal
display or Control external heating pump or Control circulation
pump
Flue gas sensor
Gas pressure monitor
Table 5.2 Accessories and external installation components
Note!
For the gas pressure monitor, several switches
having safety functions can be connected to the
small voltage input of the installation
thermostat (in series).
24
Connection
Electronic box plug socket X 8
Electronic box ProE plug "Installation thermostat"
The accessories are and ancillary connection box which contains the
functions referred to. It is connected to the control box for control of
the components: plug socket X 7
The accessories can be used for two of the functions referred to - the
setting of the required function is undertaken on the accessories. It
is connected to the control box for control of the components: plug
socket X 7
Plugs are incorporated in the wiring harness, connection instead of
standard replacement resistance fitted
Connection to ProE plug: Installation thermostat, plug socket X 1
The water shortage safety device, external controllers
and similar items must be connected via potential-free
contacts.
The controllers shown in Table 5.1 can be used for the
control of the Vaillant atmoCRAFT and the heating
system. The installation should be undertaken in
accordance with the individual operating instruction
manuals.
Installation and maintenance manual atmoCRAFT