10 ZAUNZULEITUNGS- UND ERDUNGSCHECK
Check fence voltage at the
Tip 2
Switch off the energiser,
connect to fence and switch
Use fence tester to check
voltage on fence. Is it more
Check grounding -> measure
voltage directly at the ground rod!
Is the voltage on the groun-
ding rod more than 1000 V?
Tip 6
36
INSTRUCTION MANUAL POWER XXL – B 9000 – B 9000-S – B 12000 – B 12000-S
1
end of the fence!
Is voltage over 6000V?
YES
on again
than 2.5/4 kV?
NO
2
YES
Improve grounding
Check the fence
Tip 5
NO
Fence connection cable is
defective.
YES
Problem solved
Check the grounding
Tip 3
Fault is on the fence. Voltage
NO
loss due to poor connections
(knots, corroded connectors,
conductor materials)
Use fence tester to check
voltage on fence. Is it more
than 2.5/4 kV?
YES
Everything is fine
Tip 7
NO
570500/12/2020/V2