• Avoid any mechanical restriction, compression or bending of
the cuff line.
• Do not allow sustained pressure in the cuff or frequent meas­
urements. The resulting restriction of the blood flow may
cause injury.
• Ensure that the cuff is not placed on an arm in which the
arteries or veins are undergoing medical treatment, e.g. intra­
vascular access or therapy, or an arteriovenous (AV) shunt.
• Do not use the cuff on people who have undergone a mas­
tectomy.
• Do not place the cuff over wounds as this may cause further
injury.
• Place the cuff on your upper arm only. Do not place the cuff
on other parts of the body.
• The blood pressure monitor can only be operated with bat­
teries.
• To conserve the batteries, the monitor switches off automati­
cally if no buttons are pressed for 3 minutes.
• The device is only intended for the purpose described in
these instructions for use. The manufacturer is not liable for
damage resulting from improper or careless use.
Storage and Care
• The blood pressure monitor is made up of precision electron­
ic components. Accuracy of readings and the instrument's
service life depend on careful handling.
– You should protect the device from impact, moisture, dirt,
major temperature fluctuations and direct exposure to the
sun's rays.
– Never drop the device.
All manuals and user guides at all-guides.com
• Do not press any buttons until the cuff is in position.
• If the instrument is not used for any length of time, we
• If your skin or eyes come into contact with battery fluid, flush
• Observe the plus (+) and minus (­) polarity signs.
• If a battery has leaked, put on protective gloves and clean
• Protect the batteries from excessive heat.
• Do not charge or short­circuit batteries.
• If the device is not to be used for a long period, take the bat­
• Use identical or equivalent battery types only.
• Always replace all batteries at the same time.
• Do not use rechargeable batteries.
• Do not disassemble, split or crush the batteries.
14
– Do not use near strong electromagnetic fields, i.e. keep it
away from any radio systems and mobile phones.
– Only ever use the cuffs provided with the monitor or origi­
nal replacement cuffs. Otherwise erroneous results will be
recorded.
recommend removing the batteries.
Notes on handling batteries
out the affected areas with water and seek medical assis­
tance.
Choking hazard! Small children may swallow and choke
on batteries. Store the batteries out of the reach of small
children.
the battery compartment with a dry cloth.
Risk of explosion! Never throw batteries into a fire.
teries out of the battery compartment.