Herunterladen Inhalt Inhalt Diese Seite drucken

Connection Via M12 Connector - Lenze Smart Motor m300 Bedienungsanleitung

Drehstrommotoren
Vorschau ausblenden Andere Handbücher für Smart Motor m300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electrical installation
Motor connection

Connection via M12 connector

Connection via M12 connector
NOTICE
In the "DI/DO-GND bridged" version, the masses of the control terminal X1 and X2 (GND-I and GND-O) are
connected to each other. If only one speed is used, the connection to X2 is sufficient.
Control connection X1
M12 A coded X1
Contact
1
2
3
4
Control connection X2
M12 A coded X2
Contact
1
2
4
3
Connection data - digital inputs for control connection X1/X2
Name
DI1
DI2
DI3
66
3
4
Name
n.c.
DI2
GND-I
DI1
3
4
Name
24V
DI3
DO1
GND-O
Supply voltage
24 (19.2 ... 28.8)
2
1
Meaning
Digital input 2
Ground of digital input
Digital input 1
2
1
Meaning
24 V supply (DO1 supply)
Digital input 3 (reference X1;3 = GND-I)
Digital output 1
Ground of digital output
V
in
DC V
Internal resistance
R
i
5600

Werbung