MANUAL FUNCTION / PULSE FUNCTION
If the instrument is in OFF position press button (3) once to enter into the MANUAL function; the ON/
OFF LED and the MANUAL LED are illuminated, all laser lines are on. Now the instrument can be
used in slope mode, the compensator alarm is off.
Press button (3) a second time to switch on the receiving mode; the pulse LED is illuminated, the
laser lines are weaker. The receiving mode in MANUAL function is also available.
Press button (3) a third time to deactivate all active functions (MANUAL function, receiving mode,
instrument off).
If the instrument is in ON position press button (3) to switch on the receiving mode, press button (3)
again to switch it off.
USE WITH RECEIVER (OPTIONAL)
To extend the working range of the laser or at unfavourable light conditions the 360° Liner SP can be
used with the receiver (the receiver is optional).
Note:
When using the pulse function all laser lines will be a little bit weaker than usual.

ACCURACY CHECK

Set up the instrument about 5 m from a wall. Switch the instrument on and wait until the self-levelling
procedure is completed. Mark a laser line A on the wall. Turn the instrument by 90° and mark laser
lines B, C and D on the wall. Measure the distance between points A, B, C and D. If the largest
distance between two points is ≤ 2 mm the instrument must be adjusted. Please contact your local
dealer.