  • DEUTSCH, seite 1
Dimensions
RO-T2
B
Dimensions
Height
Width
Corpus depth
Weight
Weight
Flue pipe connection
R - Ø Flue pipe outlet
RO - H original angle pipe connection height
RO - T1 original angle pipe total depth
RO - T2 original angle pipe distance to rear wall
RO - T3 Depth from rear wall to middle of flue
pipe
RO - S original angle pipe side distance
R - H Rear connection height
R - S Rear connection side distance
Fresh air connection
F - Ø Diameter
F - H Connection height
F - S Side distance
Convection air connection
K - Ø Diameter
K - H Connection height
K - S Side distance
Amount of fuel
Nominal load
Amount of fuel
*Practical values may vary depending on fuel quality.
RO-S
R-
RO-T3
K1-S
K2-S
T
F-
RO-T1
[mm]
[mm]
[mm]
[kg]
[mm]
[cm]
[cm]
[cm]
[cm]
[cm]
[cm]
[cm]
[mm]
[cm]
[cm]
[mm]
100/100
[cm]
[cm]
Part load
~2,4 kg*
~1,2 kg*

Technical data

Technical Data
Heating power range
Room heating capacity (depending on house
R-S
insulation)
Fuel consumption
Electric supply
Average electrical input
Fuse
Efficiency
CO2
F-S
CO-emission on 13% OO
Dust emission
Exhaust
Exhaust temperature
1098
Chimney draft requirement
817
424
* without convection fan
The owner of small firing systems or the person authorised for the small
firing system is to keep the technical documentation and is to submit it to the
authorities or the chimney sweep on request.
~245
Note
Please observe the national and European standards as well as local
130
regulations concerning the installation and operation of firing installations!
161
Packaging
54
17
Your first impression is important to us!
The packaging of your new stove provides excellent protection against damage.
21
However damage to the stove and accessories may still occur during transport.
25
Note
96
Therefore please check your stove on receipt for damage and completeness!
Report any deficiencies to your dealer immediately! Pay particular attention
16
during unpacking that the stone panels remain intact. Scratches to the
material can easily occur. Stone panels are excluded from the warrant.
125
The packaging of your new stove is environmentally neutral to a great extent.
14
Tip
25
The wood used in the packaging has not been surface treated and may
therefore be burnt in your woodburning stove (not in a pelletstove!). The
cardboard and film (PE) can be depolluted via the municipal waste collection
for recycling.
75/60
19/31

Electrical connection

The stove is supplied with an approx. 2m long connecting cable with a Euro-
plug. This cable is to be connected to a 230Volt/50Hz socket. The average
electrical power consumption is about 4 Watt in heating operation and approx.
150 Watt during automatic ignition. The power consumption of the convection
fan depends on the defined settings, max. up to 20W. The connection cable
must be laid in a way that there is no contact to any sharp edges or hot surfaces
of the stove.
[kW]
4,5 - 9
[m³]
110 - 240
[kg/h]
up to 2,4
[V]/[Hz]
230/50
[W]
~ 4*
[A]
2,5 AT
[%]
83,8
[%]
10,6
[mg/m
]
672
3
N
[mg/m
]
21,5
3
N
[g/s]
6,7
[°C]
242,6
[Pa]
12