packet of original Miele dustbags con-
tains one AirClean exhaust filter. Mul-
tipacks contain 4 AirClean filters (avail-
able depending on country).
b AirClean Plus 50 (light blue)
Replace this filter after approx. one
year. Make a note of the date on the fil-
ter.
c Silence AirClean 50 (grey)
d Active AirClean 50 (black)
e HEPA AirClean 50 (white)
Replace these filters when the
timestrip® filter change indicator is
completely red (Fig. 11). The indicator
lights up after approximately 50 hours
of operation, which is equivalent to
about a year of average use. You can
continue vacuuming when the light
comes on. However, the suction power
will be reduced as will the effectiveness
of the filter if it is not replaced in good
time.
Replacing the AirClean exhaust
filter (Fig. 31 + 32)
Do not use more than one exhaust
filter at a time.
 Open the dust compartment lid.
 Press the release catch on the filter
grille and open the grille until it clicks.
 Grasp the used AirClean exhaust filter
by one of the clean, unsoiled sections
and take it out.
 Replace it with a new AirClean ex-
haust filter.
44
If you wish to fit an AirClean Plus 50,
Silence AirClean 50, Active
AirClean 50 or HEPA AirClean 50 filter,
see the "Replacing one type of ex-
haust filter with another" section.
 Close the filter grille.
 Close the dust compartment lid.
Replacing the AirClean Plus 50,
Silence AirClean 50, Active AirClean
50 and HEPA AirClean 50 exhaust fil-
ters (Fig. 33 + 34)
Do not use more than one exhaust
filter at a time.
 Open the dust compartment lid.
 Lift the exhaust filter and remove it.
 Insert a new exhaust filter, making
sure it goes in properly, then press it
down into position.
 If you are using exhaust filter c, d or
e, you must also activate the
timestrip® filter change indicator (Fig.
09).
After approx. 10–15 seconds, a thin red
line will appear in the left-hand side of
the display (Fig. 10).
If you wish to fit an AirClean exhaust
filter, see "Replacing one type of ex-
haust filter with another".
 Close the dust compartment lid.