Herunterladen Inhalt Inhalt Diese Seite drucken

When To Change The Motor Protection Filter; How To Change The Motor Protection Filter; When To Replace The Exhaust Filter; How To Replace The Airclean Exhaust Filter - Miele Complete C2 SF 3 Serie Gebrauchsanweisung

Bodenstaubsauger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
A safety device prevents the lid clos-
ing without a dustbag in place. Do
not use force!
 Insert the hose connector into the
suction socket on the vacuum
cleaner until it clicks into position. To
do this, line up the guides on the two
pieces (dia. 01).
When to change the motor protection
filter
Replace this filter every time you start a
new packet of dustbags.
Every packet of original Miele dustbags
contains a motor protection filter. Mul-
tipacks contain four motor protection
filters.
How to change the motor protection
filter (dia. 33)
 Open the dust compartment lid.
 Pull the dustbag out by the grip on
the collar.
 Lift up the filter frame until it clicks
and remove the old filter. Hold by the
clean, unsoiled section to remove it.
 Replace with a new motor protection
filter.
 Close the filter frame.
 Fit the dustbag into the holder as far
as it will go.
 Close the dust compartment lid se-
curely, making sure it clicks into posi-
tion. Take care not to trap the dust-
bag when doing so.
42

When to replace the exhaust filter

Depending on model, your vacuum
cleaner will be fitted as standard with
one of the following exhaust filters (dia.
12).
a AirClean
Replace this filter every time you start a
new packet of dustbags. Every packet
of original Miele dustbags contains one
AirClean exhaust filter. Multipacks con-
tain four AirClean filters.
b Active AirClean 50 (black)
c AirClean Plus 50 (light blue)
d HEPA AirClean 50 (white)
Replace this filter when the exhaust fil-
ter timestrip indicator is completely red
(dia. 17). The indicator lights up after
approximately 50 hours of operation
which is equivalent to about a year of
average use. You can continue vacuum-
ing when the light comes on. However,
the suction power will be reduced as
will the effectiveness of the filter if it is
not replaced in good time.
How to replace the AirClean exhaust
filter (dia. 34 + 35)
Do not use more than one exhaust fil-
ter at a time.
 Open the dust compartment lid.
 Release the filter grille and raise it up-
wards as far as it will go.
 Grasp the used AirClean filter by the
clean, unsoiled section and take it out
(see arrow).
 Replace it with a new AirClean ex-
haust filter.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Complete c2 sf 4 serieComplete c2Complete c2 parquet ecoline sfrp3Complete c2 excellence ecoline sfrp3Complete c2 black pearl powerline sfaf3

Inhaltsverzeichnis