Fuel Load Sizes and Thermal Output

The thermal output depends on the amount of fuel you put in
the stove. When adding more fuel, please do not exceed the
maximum fuel load size of 2,5 kg. Exceeding the maximum
fuel load size leads to a danger of overheating, which can
result in damage to the stove and the risk of a stove fi re.
NOTE!
To attain a thermal output of approx. 9 kWm,
burn wood logs that weigh 2.5 kg and are no
longer than 30 cm in length for about 55 min.
NOTE!
To attain a thermal output of approx. 4,5 kWm,
burn wood logs that weigh 1 kg and are no
longer than 25 cm in length for about 40 min.
The Kairo is intended for intermittent operation, please only
apply one fuel layer at a time.
Dimensions in cm

5 . Initial Operation

NOTE!
During shipment, condensation moisture can
accumulate in the stove's interior, which may
possibly lead to the appearance of
condensation or water on the stove or fl ue
pipes. Please dry off these damp areas imme
diately.
The surface of your stove was treated in a sandblasting
machine before applying the colour coating. Despite careful
and thorough inspection, there may still be some residual
material in the stove body, which can fall out when your stove
is being installed.
NOTE!
To prevent any damage, please immediately
vacuum up these small steel pellets with a
vacuum cleaner.
The fi rst time a stove is operated, the heat development causes
the emission of volatile components from the coating, sealing
strips and lubricants, and smoke and odours can occur.
At a higher combustion temperature, this one-time process can
take between 4 to 5 hours.
To achieve this higher combustion temperature, please incre-
ase the fuel quantity recommended
in Section 7, „Adding Fuel/ Heating with Nominal Thermal
Output", by approximately 25%.
CAUTION!
To prevent adverse effects on health, nobody
should stay in the room(s) during this process
unless absolutely necessary. Make sure the