Data Format
For explanations on the data format required by the LCD please refer to the LCD supplement.
A 2-Byte data set is communicated between STATION and IO extension, which is defined by the
variables EXT_PORT and LED_PORT in the user program. These variables render information on the
actual state of the two 8-bit ports of the I/O terminal. The LED_PORT is only for control of the LEDs,
the EXT_PORT is brought out.
The following functions are assigned to the bits:
LED_PORT:
Bit 0:
LED 1 red
Bit 1:
LED 1 green
Bit 2:
LED 2 red
Bit 3:
LED 2 green
Bit 4:
LED 3 red
Bit 5:
LED 3 green
Bit 6:
LED 4 green
Bit 7:
LED 5 green
Warning:
Please bear in mind that the LED is turned on, if the associated bit is 0.
EXT_PORT:
Every bit b0-b7 is assigned to the associated port P1-P8.