Herunterladen Inhalt Inhalt Diese Seite drucken

D) Function H4 "Optimum Start - Sygonix TX 4 Bedienungsanleitung

Raumthermostat mit display "tx.4"
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

d) Function H4 "OPTIMUM START"

The function "OPTIMUM START" is only available in heat-
ing mode (see chapter 10. a).
Depending on connected heating, room size and environmental
conditions, the connected consumer may be activated earlier to
reach the desired temperature more quickly. The room thermo-
stat remembers how long it took on the previous day, and then
starts the connected consumer earlier accordingly.
Example: The starting time of the consumer is programmed for
06:00 for every day of the week.
When the heating process has taken, e.g, 30 minutes to reach
the desired temperature on Monday, the consumer is activated at
05:30 already on Tuesday.
If, however, the desired temperature was reached after heating
for 25 minutes already in Tuesday, the consumer will only be acti-
vated art 05:35 on Wednesday.
As you can see, the time for activating the consumer adjusts de-
pending on the duration of the heating process on the previous
day.
Proceed as follows:
1.
After selecting this function H4 "OPTIMUM START" and con-
fi rming with "OK" (2), either "YES" or "NO" fl ashes.
2. Use the buttons "–" (5) and "+" (6) to select:
"YES" = function "OPTIMUM START" on
"NO" = function "OPTIMUM START" off
3. Confi rm the setting with "OK" (2).
The room thermostat is then in the previous menu for selec-
tion of functions again.
To leave the menu and return to the regular display, push the
button "MENU" (3), repeatedly if required.
80
The home technology brand for the entire house. More information at www.sygonix.com