Note:
If the correction value exceeds or undercuts the upper
or lower temperature limit (for setting, see chapter 9. g),
the saved temperature changes!
Example:
Lower temperature limit: +5.0 °C
Upper temperature limit: +45 °C
Correction value: 0.0 °C
P1 = 5.0 °C, P2 = 12.0 °C, P3 =45.0 °C, P4 = 20.0 °C
If you set the correction value to -3.0 °C, the function G2
displays the following temperatures:
P1 = 5.0 °C, P2 = 9.0 °C, P3 = 42.0 °C, P4 = 17.0 °C
If you set the correction value back to 0.0 °C, the func-
tion G2 displays the following temperatures:
P1 = 8.0 °C, P2 = 12.0 °C, P3 = 45.0 °C, P4 = 20.0 °C
If you set the correction value to +3.0 °C, the function G2
displays the following temperatures:
P1 = 11.0 °C, P2 = 15.0 °C, P3 = 45.0 °C, P4 = 23.0 °C
If you reset the correction value to 0.0 °C, the function
G2 displays the following temperatures:
P1 = 8.0 °C, P2 = 12.0 °C, P3 = 42.0 °C, P4 = 20.0 °C
The temperature saved for P1 and P3 has changed based
on the temperature limits (marked in bold at the top).
If required, the temperatures in function G2 "PROGRAM
SETTING" therefore must be accordingly reset manually!