Ex RC ... -3G/D
//
Montage- und Anschlussanleitung / Magnetsensor
Mounting and wiring instructions / Magnetic sensor
Instructions de montage et de câblage / Capteur magnétique
Istruzioni di montaggio e collegamento / Sensore magnetico
Instruções de montagem e instalação / Sensor magnético
Инструкция по монтажу и подключению / Магнитный датчик
English
Special conditions and »X« marking
- Lay the cable securely to protect it from mechanical damage.
- If the connection is carried out within an explosive hazardous areas,
connect the cable inside an enclosure which meets the requirements
of an approved ignition protection type per EN 60079-0.
- Install the magnetic sensor Ex RC 12 and magnetic sensors with a
»4J« marking in such a way as to protect them from
mechanical damage.
- The maximum short circuit current I k of the supply source may not
exceed the I k value given on the product label.
Installation, mounting, dismantling
=
DANGER
Live parts. Explosive atmosphere. Explosion haz-
ard! Risk of burns! Connecting and disconnecting
only to be performed by qualified and authorised
personnel. Connecting and disconnecting only in
non-explosive environment.
Mount the device on an even surface. Do not use the device as a me-
chanical endstop. Any mounting position is possible. The mounting
distance between two magnetic sensors must be min. 50 mm. Keep
away ferromagnetic cuttings, do not mount in strong magnetic fields
and on ferromagnetic materials. If necessary, mount 20 mm of
non-ferromagnetic material around the magnetic sensor. Mount mag-
netic sensor and actuating magnet so that they centrically align with
each other. Do not fix with ferromagnetic mounting material. Depend-
ing on the electrical load the magnetic sensor must be protected from
voltage and current peaks by suitable protection circuits. It is re-
quired to distinguish between ohmic, inductive and capacitive load.
The magnetic sensor must not be installed within dust-explosive en-
dangered areas where propagating brush discharge can occur.
Application and operation
=
DANGER
In case of overloaded contacts too high operation
temperatures. Explosion hazard! Risk of burns! For
short-circuit protection observe correct fuse size.
- Use device only within the permitted electrical load limits (see
technical data).
- Use device only within the permitted ambient temperature range
(see product label and technical data).
Cleaning
- Use a damp cloth to clean devices in explosive hazardous areas. This
prevents electrostatic charge.
- In case of damp cleaning: use water or mild, non-scratching,
non-chafing cleaners.
- Do not use aggressive cleaners or solvents.
Disposal
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately.
Service, maintenance, repair
=
DANGER
Live parts. Electric shock hazard! Do not repair de-
fective or damaged devices. Replace them.
=
DANGER
Explosive atmosphere. Risk of burns! Do not re-
build or modify the device in any way.
With rough conditions, we recommend routine maintenance as follows:
1. Removal of all dirt particles.
2. Check sealing of the cable or conduit connections.
N.B.
The electrical connection may only be carried out by authorised per-
sonnel. Reconstruction and alterations to the device which might af-
fect the explosion protection are not allowed. Furthermore, EN 60079-
14 has to be applied for the installation of electrical equipment in ex-
plosive hazardous areas. Moreover, the ATEX test certificate and the
special conditions therein have to be observed. It is the responsibility
of the manufacturer of a plant or machine to guarantee the correct
general function. Subject to technical modifications. steute does not
assume any liability for recommendations made or implied by this de-
scription. New claims for guarantee, warranty or liability cannot be de-
rived from this document beyond the general terms and conditions
of delivery.
Français
Utilisation des instructions de montage et de câblage
Groupe cible: personnel autorisé et compétent.
Toutes les manipulations décrites dans cette notice d'installation ne
doivent être effectuées que par du personnel formé et autorisé par la
société exploitante.
1. Lire et comprendre les instructions de montage et de câblage.
2. Respecter les règles de sécurité et de prévention des accidents en
vigueur.
3. Installer l'appareil et le mettre en service.
La sélection et l'installation des appareils et leurs intégrations dans
les systèmes de commande exigent une connaissance approfondie
de toutes les lois pertinentes, ainsi que des exigences normatives du
fabricant de la machine.
En cas de doute, la version allemande fait référence.
Volume de livraison
1 appareil, 1 instruction de montage et de câblage, carton.
3 / 16