Herunterladen Inhalt Inhalt Diese Seite drucken

Memorization Procedure Of The Stroke - tau TSKY-B Bedienungs- Und Wartungsanleitung

Vorschau ausblenden Andere Handbücher für TSKY-B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 37
Resistive sensitive edge input (DIP 10=ON);
sensitive edge input – fixed edge (DIP
SENSITIVE
10=OFF); 1 = Sensitive edge; 2= Common.
1 - 2
EDGE
If neither the resistive sensitive edge nor
the fixed edge are used, set DIP 10 to OFF
and short circuit terminals 11 and 12;
3 - 4
BUS CIRCUIT
Device input with BUS system.
433,92 MHz built-in RX aerial input; 5=
5 - 6
AERIAL
Earth - 6= Signal;
Quick coupling for the connection of the
J2
AUX
T-WIFI and T-CONNECT devices
Quick
J3
MEMORY CARD
connection for transmitters codes.
COURTESY
Quick coupling for the connection of the
J4
COURTESY LIGHT led
LIGHT
MOTOR +
quick coupling for the connection of the
J5
ENCODER
MOTOR + ENCODER.
IMPORTANT:
do not connect switching feeders or similar apparatus close to
the control unit that may be a source of disturbance.
4.4. LOGIC ADJUSTMENTS
TRIMMER
FR
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the
gearmotor to obstacles diminishes and therefore the thrust force
increases; vice-versa, by rotating it counter-clockwise, the sensi-
tivity of the gearmotor to obstacles increases and therefore the
thrust force diminishes.
DIP-SWITCH
when opening is complete, the closing of the sec-
tional door is automatic after 60 sec.
On
NOTE: the adjustment of the automatic clo-
AUTOMATIC
1
sing time can be carried out ONLY via TAU
CLOSING
APP (with T-WIFI device)
Off
automatic closing disabled.
with automatic closing enabled, a sequence of
On
open/close commands causes the sectional door
to OPENCLOSE-OPEN-CLOSE etc.
2
2 / 4 STROKE
in the same conditions, the same command se-
Off
quence causes the sectional door to OPEN-STOP-
CLOSESTOP-OPEN-STOP (step-by-step).
during opening the sectional door ignores any
On
closing commands.
NO
3
the sectional door's behavior depends on the
REVERSE
Off
position of dip switch No.2. The direction can be
reversed also during the opening manoeuvre.
On
the "BUS photocells check" function is enabled.
the "BUS photocells check" function is disabled.
4
PHOTOTEST
Off
Note: leave in OFF position when photocells
are not used.
preflashing enabled, each time the gate is oper-
On
ated the light starts flashing 3 seconds before the
PRE-
gate begins to move.
5
FLASHING
when the gate is started, it will move immedi-
Off
ately.
Force value increased during the storage phase
On
for sectional doors with sliding problems during
FORCE IN
opening / closing
6
STORAGE
Normal force value during the storage phase
PHASE
Off
for sectional doors without sliding problems du-
ring opening / closing
parameter increased for the realignment of the
On
belt / chain after closing.
7
BACKJUMP
standard parameter for the realignment of the
Off
belt / chain after closing.
On
GARAGE
use for overhead door with 100BANT accessory
8
DOOR SE-
Off
use for sectional door
LECTION
plug-in
for
MEMORY
CARD
parameter increased for the deceleration point
On
of the sectional door in the opening / closing
phase.
DECELERA-
9
TION
standard parameter for the deceleration point
Off
of the sectional door in the opening / closing
phase.
IMPORTANT: the position of the sectional opening limit
switch is uploaded during setup ONLY the first time the
procedure is carried out (LEDs DL1 and DL2 alternating
red / green light). To change the position it is necessary
to carry out, before a new setup procedure, a "FACTORY
RESET" (see page 9).
resistive sensitive edge connected. Connect the
On
resistive sensitive edge, with the related 8,2 KΩ
resistance, to terminals 1-2.
SENSITIVE EDGE WITH NORMALLY CLOSED CON-
SENSITIVE
Off
TACT (N.C.) Connect the sensitive edge to termi-
10
EDGE
nals 1-2.
Note: If no sensitive edge is used, set the DIP
SWITCH 10 to OFF and short-circuit the termi-
nals 1-2.
IMPORTANT:
Each pair of terminals attached to an NC contact that is not in use
must be short-circuited in order to ensure the proper operation
of the board.
4.5. PROCEDURE FOR STORING ANY BUS ACCESSORIES
ATTENTION: After powering the control panel, wait for 2 seconds
before starting to carry out the adjustment maneuvers.
If there is a need to equip the automation with any accessories such as
photocells, flashing light, key selector, push-button panels, it will be
necessary to use only products operating with the BUS protocol.
After installing and connecting to the control unit the accessories, if
any, they will be stored according to the following procedure:
1_ Press the button P2 until the yellow LED DL3 starts flashing conti-
nuously, then release the button.
2_The yellow LED will always remain on, indicating that the memoriza-
tion of the BUS accessories, if any, has been successful.
Note: If there are no accessories, the above procedure will not need
to be carried out..

4.6. MEMORIZATION PROCEDURE OF THE STROKE

NOTICE: Before making the automation perform any movement,
make sure that the sectional door has the necessary safety stops
for both opening and closing.
To memorize the stroke:
1_ bring the sectional door to approx. 1 m from the fully closed posi-
tion;
2_ press buttons P1 and P2 simultaneously for about 5 sec.;
3_ the sectional door will start to open.
Note: If it closes, suspend the programming by resetting the electric
panel (remove the power supply to the panel for at least 5 seconds),
and then with the panel disconnected, invert the power supply wi-
res of the motor(s). Then resume the procedure from the 1st step.
Note: if the automation remains stationary, check the connections
of the inputs. Check that the DL4 LED is always on and if there are
any BUS accessories connected, the yellow DL3 must also be on,
while if no accessory is connected to terminals 3-4, the yellow DL3
will flash every 2 sec.
4 once is fully opened, the automation starts closing in search of the
closing stop (in this phase the control unit acquires all the parame-
ters relating to the stroke);
5 the automation performs a complete opening for the optimization of
the motor force during opening;
6 after a short pause, the automation performs a complete closure to
optimize the motor force during closure.
7_ when closing is complete, wait for the error signaling LED (DL2) to
flash every 4 sec.;
8_ the automation is now ready for normal operation.
ATTENTION:
- The procedure can be interrupted by pressing the STOP key.
23

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tsky1-bK995ma-s

Inhaltsverzeichnis