Herunterladen Inhalt Inhalt Diese Seite drucken

Hilti DD 200/DD-HD 30 Bedienungsanleitung Seite 50

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6.5
PRCD ground fault circuit interrupter
1. Plug the diamond core drilling machine's mains plug into an earthed/grounded power outlet.
2. Press the "I" or "RESET" button on the PRCD ground fault circuit interrupter.
▶ The indicator lights up.
3. Press the "0" or "TEST" button on the PRCD ground fault circuit interrupter.
▶ The indicator goes out.
WARNING
Risk of injury due to electric shock! Do not continue operating the diamond core drilling machine if the
indicator on the ground fault circuit interrupter does not go out when the 0 or the TEST button is pressed.
▶ Have your diamond core drilling machine repaired by Hilti Service.
4. Press the "I" or "RESET" button on the PRCD ground fault circuit interrupter.
▶ The indicator lights up.
6.6
Operating the diamond core drilling machine
WARNING
Risk of personal injury and material damage The diamond core drilling machine may become damaged
and the risk of electric shock is increased.
▶ Use of the water collection system in conjunction with a wet-type industrial vacuum cleaner is a mandatory
requirement for wet drilling overhead.
DANGER
Risk of personal injury and material damage The wet-type industrial vacuum cleaner switches on and off
with a delay. This allows water to run over the diamond core drilling machine. The diamond core drilling
machine may become damaged and the risk of electric shock is increased.
▶ When drilling in an upward direction, the wet-type industrial vacuum cleaner must be switched on
manually before opening the water supply valve and switched off again manually after closing the water
supply valve.
DANGER
Risk of personal injury and material damage The diamond core drilling machine may become damaged
and the risk of electric shock is increased.
▶ When drilling in an upward direction, stop working if the suction removal system stops working (e.g. the
wet-type industrial vacuum cleaner is full).
WARNING
Risk of personal injury and material damage The water collector cannot function correctly during drilling
in an upward direction at an angle. The diamond core drilling machine may become damaged and the risk
of electric shock is increased.
▶ Do not drill in an upward direction at an angle.
1. Slowly open the water flow regulator until the desired volume of water is flowing.
2. Press the On/Off switch on the diamond core drilling machine to "I".
3. Release the carriage locking mechanism.
4. Turn the hand wheel until the core bit is in contact with the base material.
5. When beginning drilling, apply only light pressure, until the core bit has centered itself. Only increase the
pressure afterwards.
6. Regulate the contact pressure while observing the drilling performance indicator.
42
English
2274306
*2274306*

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dd 200/dd-st 200

Inhaltsverzeichnis