Herunterladen Inhalt Inhalt Diese Seite drucken

Magnescale SmartSCALE SQ47-Z Serie Bedienungsanleitung Seite 44

Vorschau ausblenden Andere Handbücher für SmartSCALE SQ47-Z Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Example 2: Installation when a stop surface of the scale and the sensor head is not made with
the bracket.
1. Adjust the parallelism of the scale bracket and sensor head bracket with respect to the machine guide,
and then secure in place.
Adjust the height and parallelism of the sensor head bracket with respect to the scale bracket, and then
secure in place.
Sensor head
bracket
0.05 A
Sensor head
bracket
Scale
bracket
A
2. Check the label attached to the scale to confi rm the sensor head cable extension direction and make
sure that the serial No. matches that of the sensor head. (See Fig. 3-6.)
3. Remove the label. (See Fig. 3-7.)
4. Adjust the parallelism with respect to the machine guide while measuring surface A with a dial gauge,
and tighten the set screws.
<Measurement method>
Measure near the positions at both ends of the eff ective length on surface A.
A side (installation guide)
12
(E)
MG
0.05
0.1 MG
Scale
bracket
Fig. 3-10
0.2 MG
Fig. 3-11
A
Scale bracket
0.05 A
0.1 MG
Unit: mm
Unit: mm
SQ47-Z Series, CH22 Series

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Smartscale ch22 serie

Inhaltsverzeichnis