1-5. Functional Safety

Th is product is a functional safety magnescale which is compliant with EN 61800-5-2:Ed. 2.0: 2016 /
IEC 61508:2010 / IEC 62061:2005 SC3 SIL 2 and EN ISO 13849-1:2015 Cat.3 / PL d.
Behavior of the product when a fault arises.
Dangerous fault : An error
Safe state
: Th e product sends the alarm information to the controller via the DQ100, holds
the alarm information, and shift s to a safe state.
Recovery process : When the magnescale trouble is resolved, normal communication is restored
immediately aft er the product receives the Alarm Reset signal from the
controller. Otherwise, the alarm is held.
(*1) : Th e error position information described here is a threshold value which is considered as a dangerous
fault value in terms of functional safety and is not the accuracy of the product. As for the accuracy
of the product, see Section 6. "Specifications."
Th e product is maintenance-free and it is not necessary to replace the parts periodically.
Functional safety specifi cations
Item
Operating temperature : +50°C
Probability of
Operating temperature : +25°C
dangerous failure
Operating temperature : 0°C
MTTFd
DCavg
Hardware fault tolerance
Product type
SIL
SC (Systematic capability)
Normative references
Standard
IEC 61508:2010
IEC 62061:2005+A1: 2012+A2: 2015
EN ISO 13849-1:2015
IEC 60664-1:2007
EN 61800-5-2:E.d. 2.0: 2016
IEC 62061:2005+A1: 2012+A2: 2015
IEC 60068-2-1, IEC 60068-2-2,
IEC 60068-2-6, IEC 60068-2-14,
IEC 60068-2-27, IEC 60068-2-30,
IEC 60068-2-31
IEC 61000-6-4:2006 +A1:2010
CISPR 16-1-1:2010, clause 4
CISPR 16-1-4:2010, clause 4.4 and 5
CISPR 16-2-3:2010, clause 7.2
IEC 61000-6-2:2016
IEC 61326-3-1:2017
IEC 61000-4-2:2008
IEC61000-4-3:2006 +A1:2007 +A2:2010
IEC 61000-4-4:2012
IEC 61000-4-6:2013
IEC 61000-4-8:2009
For details about functional safety, contact our functional safety department.
45 Suzukawa, Isehara-shi, Kanagawa 259-1146, Japan TEL: +81 (0)463 92 1011 FAX: +81 (0)463 92 1012
SQ47-Z Series, CH22 Series
: Th e product shift s to a safe state within 5 ms when a
dangerous fault is detected.
(
*
1)
in position measurement exceeds ±1 mm of reference.
Mode of operation
High demand / continuous mode
PFH = 38 × 10
PFH = 10 × 10
PFH = 5.7 × 10
85.4 years (High)
79.08% (Low)
1
Type B
2
3
Applied specifi cation
Functional safety
Functional safety
Functional safety
Clearances (between PWB (Printed wiring board) patterns)
specifi cation
Requirements related to Table D.16 Motion and position
feedback sensors
Table D.1 Failure Mode
Environmental Tests
Emission
Immunity
-9
(1/h)
-9
(1/h)
-9
(1/h)
3
(E)