If necessary, lubricate the pins and moving parts of the spring catches, taking care to remove excess lubricant. You can use small quantities of multi-purpose grease or synthetic
lubricant.
Use only original or Spencer Italia S.r.l. approved components/replacement parts and/or accessories to carry out any operation without causing alterations or modifications
to the device. Otherwise, we decline all responsibility regarding incorrect operation or any damage caused by the device to the patient or the operator, invalidating the
warranty and invalidating compliance with EU Regulation 2017/745.

12.3 PERIODIC OVERHAUL

No periodic overhaul is foreseen for the device.

12.4 SPECIAL MAINTENANCE

Special maintenance can only be carried out by the Manufacturer, who uses internal and external technicians specialised and authorised by the Manufacturer itself. .
Only maintenance activities carried out by specialised technicians authorised by the Manufacturer are considered valid by Spencer Italia S.r.l..
The end-user can replace only the spare parts indicated in § 15.

12.5 LIFE SPAN

The device, if used as described in the following instructions, has an average life span of 5 years from the date of purchase.
Spencer Italia S.r.l. will accept no responsibility for incorrect operation or damage caused by the use of devices that have exceeded the maximum allowable life span.

13. TROUBLESHOOTING TABLE

PROBLEM
The spring catch locking ring does not rotate (STX519).
The spring catch does not close.
Components otherwise damaged.
If a problem or fault is detected that does not correspond to the above, please contact Spencer Italia srl customer care service.

14. ACCESSORIES

There are no accessories for these devices.

15. SPARE PARTS

There are no accessories for these devices.

16. DISPOSAL

When devices and their accessories are no longer suitable for use, they can be disposed of as normal municipal solid waste if they have not been contaminated by special
agents. Otherwise, follow the regulations in force regarding disposal.
The information contained in this document is subject to change without notice and is to be intended as a commitment by Spencer Italia S.r.l. subject to change. Spencer
products are exported to many countries where the same rules do not always apply. For this reason, there may be differences between what is described herein and the
products delivered. Spencer is constantly working on improving all types and models of the products sold. We therefore rely on your understanding if we should reserve the
right to make changes to the scope of delivery at any time in terms of form, equipment, set-up and technology.
All rights reserved. No part of the document may be photocopied, reproduced or translated into another language without prior written consent from Spencer Italia S.r.l.
CAUSE
Possible dirt inside.
Possible oxidation or dirt.
Normal wear or improper use.
Warning
© Copyright Spencer Italia S.r.l.
REMEDY
Blow with compressed air until movement is released.
Lubricate if necessary.
Try localised treatment with an anti-corrosive lubricant.
For STX 540 only: if the problem persists, replace the
spring catch.
Put the device out of service immediately and replace it
with a similar one.