Cleaning evaporator
To ensure perfect operation and hygiene from the evapora-
tor, it is advisable to carry out periodically, on the basis of the
frequency of use of the machine, the internal cleaning in the
following way:
Fig. 1
Fig . 3
Remove the screws that fix the steel fan-carrying panel onto
the evaporator and open the panel as indicated
Wash the evaporator battery using a jet of hot water at low
pressure directing the jet from high to low onto the evapo-
rator. Evacuate the water and clean thoroughly.
At the end use compressed air to remove all the water on
the evaporator battery and on the fan(s).
Make sure to dry thoroughly all the parts and the compo-
nents.
Screw on the fan-carrying panel.
Before starting the machine make sure to have removed
all tools used for cleaning.
07/2013
Fig . 2
Fig . 4
BLAST CHILLER ISTRUCTION
10.5 DRAINING DEFROST WATER (if present)
The equipment is designed for manual defrosts exposed to
the air.
At the end of the defrost (if necessary) clean the inside of the
unit with a sponge and/or cloth to remove any condensa-
tion.