Pic.3 – The continuous drainage
The air filter
The air is placed behind the front grid and can be easily re-
moved for cleaning. The air filter can be cleaned with a vacuum
cleaner or with water: in this case dry it before assembly.
C
Do not run the dehumidifier without the air fil-
ter to avoid accumulating dust on the heat ex-
changer. Keep clean the air filter in particular
when al lot of dust is present in the air: a dirty
air filter reduces the air flow and the efficiency
of the dehumidifier.
How to remove the air filter
Pic.4 – The air filter
Pull the front grid upward: the air filter is behind the grid.
How to put the air filter on
Pic.5 – The air filter assembly
Apply the air filter to the back side of the front grid and insert
the wings (B) into the holes (F) (Pic.5): then fix the grid to the
bracket (S).
12

The control panel

Pic.6 – The control panel
S1 - Green light ON The green light indicates when the dehu-
midifier is operative, otherwise it blinks on status 0.
S2 - Red light, full tank The light blinks, together with the
green one S1, when the tank is full, missing or incorrectly po-
sitioned.
S3 - Yellow light, defrost The light switches on during the au-
tomatic defrosting cycle.
T1 - Decrease button Pushing this button the value of the dis-
play D will decrease down to 0 value.
T2 - Increase button Pushing this button the value of the dis-
play D will increase up to C value.
D - Display The display shows the working state of the dehu-
midifier according with Tab.B. The value 0 means OFF, from 1
to 9 means automatic functioning and it depends from the hu-
midistat that switches on or off the dehumidifier if the value of
the relative humidity is higher or lower of the one shown in the
Tab.B. The value C means ALWAYS ON and the dehumidifier
works independently from the humidity value: nevertheless
any alarm has the priority on functioning mode.
Display
Functioning
0
1
90% U.R.
2
86% U.R.
3
78% U.R.
4
72% U.R.
5
65% U.R.
Tab.B – Functioning modes
Start up
When the plug is connected the display D blinks for 5 sec-
onds and shows the last functioning mode selected: then, if
the functioning mode is different from zero, the blinking stops.
Shutdown
To switch off the dehumidifier push the button T1 until the
value displayed is 0. When zero is selected both the green light
S1 and the display D blink.
The defrosting cycle
If the temperature goes below 16°C ice may form on the evap-
orator: le electronic board automatically performs the defrost-
ing cycle to melt the ice and keep free the air flow even at lower
temperatures. During the defrosting cycle the light S3 switches
on.
Failures
The display is used by the electronic device to show particular
situations (Tab.C). If an error message is displayed please con-
tact your dealer for repair.
ENGLISH
M1290-0_draft-0
Display
Functioning
OFF
6
60% U.R.
7
52% U.R.
8
46% U.R.
9
40% U.R.
C
ALWAYS ON