5. Residual risks

Even if you use this electric power tool in ac-
cordance with instructions, certain residual
risks cannot be rules out. The following hazards
may arise in connection with the equipment's
construction and layout:
• Lung damage if no suitable protective dust mask
is used.
• Damage to hearing if no suitable ear protection is
used.
• Health damage caused by hand-arm vibrations if
the equipment is used over a prolonged period or is
not properly guided and maintained.

6. Technical data

Mains voltage
Power input
Working pressure
Working pressure max.
Delivery rate
Max. water inlet pressure
Protection class
Danger!
Sound and vibration
Sound and vibration values were measured in ac-
cordance with EN 60335.
L
sound pressure level
pA
K
uncertainty
pA
L
sound power level
WA
K
uncertainty
WA
Wear ear-muffs.
The impact of noise can cause damage to hearing.
Total vibration values (vector sum of three directions)
determined in accordance with EN 60335.
Vibration emission value a
h
The specified vibration value was established in ac-
cordance with a standardized testing method. It may
change according to how the electric equipment is
used and may exceed the specified value in excep-
tional circumstances.
The specified vibration value can be used to compare
the equipment with other electric power tools.
The specified vibration value can be used for initial
assessment of a harmful effect.
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
220-240V~ / 50-60 Hz
1400 W
7 MPa
10.5 MPa
5,5 l/min
0,4 MPa
II
79.9 dB(A)
3 dB(A)
97 dB(A)
3 dB(A)
≤ 2,5 m/s
2
Keep the noise emissions and vibrations to a
minimum.
• Only use appliances which are in perfect working
order.
• Service and clean the appliance regularly.
• Adapt your working style to suit the appliance.
• Do not overload the appliance.
• Have the appliance serviced whenever necessary.
• Switch the appliance off when it is not in use.
• Wear protective gloves.
7. Before putting the machine into
operation
Correctly using the device
• The high-pressure cleaner must be set on a level,
stable surface.
• It is recommended that you maintain the correct
operating position every time you use the machine
by placing one hand on the pistol and the other on
the lance.
• Never direct the water jet toward electrical lines or
the machine itself.
• It is normal for the pump to leak a little; this is nec-
essary to avoid damage to the pump when it is at
a standstill.
• Never use the equipment in potentially explosive
areas under any circumstances!
• The operating temperature must be between +5
and + 60°C.
• Do not cover or modify the lance or the spray noz-
zles in any way.
• The high-pressure cleaner is designed to be used
with cold or lukewarm water (max. 40°C); higher
temperatures can damage the pump.
• Do not use water that is dirty, gritty or contains any
chemical products, as these could impair operation
and shorten the life of the equipment.
Assembly
Device assembly (Fig. 2)
Attach the lance holder (1) and the cable holder (3)
onto the side of both fastening points on the device.
Push the folding carrying handle (2) onto the fasten-
ing point at the top of the device and use the included
screws to secure it.
Water supply connection (Fig. 3)
Screw the connection for the water supply (12) onto
the device. The connection for the water supply (12)
features a connection for standard hose coupling
systems. Attach the hose coupling of the supply hose
(min. Ø 1/2"/ approx. 13 mm) onto the connection for
the water supply
(12).