Remove the cover as shown in fig. 2.
Run the power supply cables through the "PC" part and the conduit in
the appliance (see fig. 6). Connect according to section "ELECTRICAL
CONNECTION"
If the assembly is done with an individual exhaust tube, place the tube
(D) in the hole prepared for air exhaust.
Whether the assembly is done with an individual exhaust tube or with a
direct outlet, air grilles must be installed that comply with national safety
requirements for preventing access to the fan blades (see fig. 1)
Make sure that there is no obstacle blocking the flow of air.
Attach the base of the casing using the plugs and screws supplied by the
manufacturer (see fig. 2).

ELECTRICAL CONNECTION:

Make sure that the voltage (V) and frequency (Hz) of the power supply
correspond to the values indicated on the nameplate.
The appliance must be permanently connected with fixed instal-
lation wiring, fitted in the wall and entering the appliance through the
rear side (see fig. 6).
No earthing connection is required, given that this is a doubly-insulated
appliance. (Class II).
The power supply cable must be placed so that no liquid or vapour
can enter the appliance along it. If this were not possible, the cable
entry should be sealed additionally, e.g. with silicone. Otherwise, the
indicated IP rating would not be maintained.
Fan with TIMER-HYGRO control. Activation by humidity control
between 40% and 95%. Adjustable timer from 0' to 15'.
Designed for continuous general ventilation of humid rooms (bathrooms,
kitchens, washing rooms and toilets).
For manual operation set humidity setting to 95%.
For the electrical connection, follow the connection diagram (see fig. 6).
In the event that this appliance is not used, it is recommended that you
disconnect it from the mains electricity supply.
SETTINGS and OPERATION:
When power is applied for the first time, the fan goes into test mode for
a few seconds, and during that time the displays show the factory-set
Timer - Hygro values.
To adjust the timer, turn the "TIMER" pin until the desired value appears
on the display (0'-15').
To adjust the level of humidity, turn the "HYGRO" pin until the desired
value appears on the display (40% - 95%).
The P14 model permits the continuous ventilation (for 24 hours) of damp
rooms through the ACTIVATION of S1 switch (S1: ON).
When the level of humidity is higher than the set level, the Hygro func-
tion is activated and the fan will operate at maximum speed.
Once the level of humidity falls below the set value, the device will con-
tinue to operate at maximum speed for the period of time set in the Timer
function, and will eventually stop if S1=OFF or continue to operate at
low speed if S1=ON.
Maximum and slow speeds are factory settings.
The extractor fan will also start, at maximum speed, if activated by the
light switch in the room. When the light switch in the room is turned off,
the fan will continue to work at maximum speed for the period of time
set in the Timer function, and will eventually stop if S1=OFF or continue
to operate at low speed if S1=ON.
To finish the installation, verify that all the connections have
been done correctly and make sure that the cables are placed correctly.
Install the front cover in its position and make sure that it cannot be
removed without using a tool (see fig. 10).
Make sure that the blades turn freely.