INSTALLATION GUIDE
build in HL62..E
The appliance can be connected in the following ways:
1 phase connection (1 1N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c.
Install connecting bridges between connection points 1-2 and 4-5.
Your group must be protected by a fuse of at least 32 A. The connecting
power cable must have a minimum core cross section of 6 mm
.
2
2 lives with 2 neutrals connection (2 2N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c. There may be a
voltage of 0 V between the phases if they are connected to the same phase
in the meter cupboard but also 400 V if they are connected to 2 different
phases. Your groups must be fused with at least 16 A (2x). The connecting
power cable must have a minimum core cross section of 2,5 mm
.
2
76