PerfectPower
WARNING! Danger of electrocution!
!
If you wish to connect more than one consumer to the inverter and
install a socket distributor loop, you must arrange a circuit breaker
(residual current circuit breaker) and set a grounding bridge in the
inverter, see "Connecting multiple consumers" on page 34.
Earthing the inverter
➤ Connect the earth connection on the inverter (fig. 2 4, page 3) with the
earth of the vehicle.
Connecting the inverter to the battery
NOTE
I
Please be aware that all volatile memories of the connected electric
consumers will lose their stored data if the battery is disconnected.
NOTICE!
A
Make sure the polarity is correct. If the positive and negative con-
nections are reversed, this may damage the device.
➤ Connect the terminal on the red battery connection cable to the positive
terminal (fig. 2 7, page 3) on the inverter.
➤ Connect the terminal on the black battery connection cable to the
negative terminal (fig. 2 6, page 3) on the inverter.
➤ Check the connections are secure.
You might have to tighten the screws again later.
NOTE
I
Sparks may be produced when the connections are made due to
the internal capacitors being charged.
➤ Connect the red battery connection cable to the positive terminal on the
battery.
➤ Connect the black battery connection cable to the negative terminal on
the battery.