PerfectPower
If the mains supply fails, the inverter switches on after 2 seconds.
NOTICE!
A
When switching over, any devices connected should be switched
off. Because they do not receive voltage for 2 s, they may have to
be switched back on.
The inverter is equipped with protection against thermal and electrical
overloading, as well as excess and insufficient voltage. The inverter switches
off:
If its internal temperature is too high
If the load exceeds the values listed in the technical data
If the input voltage is too high or too low
A single consumer or a socket distribution system can be connected to the
inverter to create an on-board 230 V supply with several sockets.
The device is equipped at delivery with galvanic isolation. For the safe
operation of multiple consumers, it is essential that a circuit breaker (residual
current circuit breaker) is built into the socket distribution circuit and the
grounding bridge is set in the inverter.
NOTE
I
Note when connecting devices with an electrical drive (such as
power drills and refrigerators), that they often need more power
than is stated on the type plate.
The inverter can be switched on manually or using a remote control.
Cooling is provided by a fan and is load-dependent.
EN
Technical description
29