BTL7-A/C/E/G5 _ _ -M _ _ _ _ -HB/WB-KA_ _/K_ _/FA_ _/F_ _
Micropulse Transducer - Rod Style
6
Calibration procedure
Output
Linear
gradient
transducer
Rising
BTL7-A...
BTL7-G...
BTL7-C...
BTL7-E...
Falling
BTL7-A...
BTL7-G...
BTL7-C...
BTL7-E...
Tab. 6-1:
Value table for teach-in and inverting
6.1

Programming inputs

Programming inputs La and Lb must be used in order to
make settings. A programming input at 10 to 30 V
corresponds to activation (high active).
The Balluff BTL7-A-CB02-K calibration box can be used
for this (see Accessories on page 23).
Automatic deactivation!
If no signals are transmitted via the
programming inputs for approx. 10 min,
programming mode is automatically ended.
6.2

Calibration procedure notes

Prerequisites
Programming inputs are connected.
The transducer is connected to the system controller.
Voltage or current values from the transducer can be
read (using a multimeter, the system control or the
calibration box).
Fig. 6-1:
Connecting the BTL7-A-CB02-K calibration box
www.balluff.com
Unit
Min.
Null
value
value
V
–0.5
0
V
–10.5
–10.0
mA
0
0
mA
3.6
4.0
V
+10.5
+10.0
V
+10.5
+10.0
mA
20.4
20.0
mA
20.4
20.0
Linear transducer
Indication
Indication
for
for
adjustment
teach-in
2.0
4.0
2.0
4.0
6.0
12.0
6.0
12.0
2.0
4.0
2.0
4.0
6.0
12.0
6.0
12.0
Values for null and end point
Any desired position of the magnet can be used as the
null or end point. However, the null and end points may
not be reversed.
The absolute null and end points must lie within the
minimum or maximum range of what can be output
(see value table).
The last set values are always saved, regardless
of whether the setting was ended using the
programming inputs or automatically after
10 min have expired.
Value table for teach-in and inverting
The following examples refer to transducers
with 0 to 10 V or 4 to 20 mA output.
YE
YE
Calibration box
8-pin
GY
GY
PK
PK
RD
RD
GN
GN
BU
BU
BN
BN
WH
WH
8-port luster terminal
End
Max.
Error
value
value
value
+10.0
+10.5
+10.5
+10.0
+10.5
+10.5
20.0
20.4
20.4
20.0
20.4
3.6
0
–0.5
–0.5
–10.0
–10.5
–10.5
0
0
20.4
4.0
3.6
3.6
Supply