Herunterladen Inhalt Inhalt Diese Seite drucken

Type Code Breakdown - Balluff BTL7-A Serie Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BTL7-A Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL7-A/C/E/G5 _ _ -M _ _ _ _ -HB/WB-KA_ _/K_ _/FA_ _/F_ _
Micropulse Transducer - Rod Style
12

Type code breakdown

Micropulse transducer
Interface:
A = Analog interface, voltage output 0...10 V
G = Analog interface, voltage output –10...10 V
C = Analog interface, current output 0...20 mA
E = Analog interface, current output 4...20 mA
Supply voltage:
5 = 10...30 V DC
Output gradient:
00 = Rising (e.g. C_00 = 0...20 mA); only with BTL7-C/E
10 = Rising + falling (e.g. A_10 = 10...0 V and 0...10 V); only with BTL7-A/G
70 = Falling (e.g. C_70 = 20...0 mA); only with BTL7-C/E
Nominal length (4-digit):
M0500 = Metric specification in mm, nominal length 500 mm (M0025...M7620)
Rod version, fastening:
HB = Metric mounting thread M18×1.5, O-ring, rod diameter 10.2 mm
WB = 3/4"-16UNF thread, O-ring, rod diameter 10.2 mm
Electrical connection:
KA05 = Cable, 5 m, axial (PUR)
K05 = Cable, 5 m, radial (PUR)
FA05 = Cable, 5 m, axial (PTFE)
F05 = Cable, 5 m, radial (PTFE)
24
english
BTL7 - E 5 0 0 - M0500 - HB - F05

Werbung