Herunterladen Inhalt Inhalt Diese Seite drucken

Adjusting The Heating Element - GF EA15 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für EA15:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Instruction manual
9.4

Adjusting the heating element

Heating adjustment inside the actuator
The heating element has been set at the factory, so it starts heating from an internal device
temperature of 0 °C (32°F). For environments with higher temperatures and high humidity,
the heating threshold must be increased, in order to prevent moisture condensation inside
the housing. The heating threshold can be set via the heating adjustment.
The following table shows the positions of the heating adjustment and in which corresponding
temperature ranges the heating element will heat.
Position heating adjustment
0 (default)
1
2
3
4
5
6
7
8
9
 In order to change the heating threshold, turn the heating adjustment with a suitable
screwdriver to the desired position.
When the heating element is heating, the dot on the 7 segment display is illuminated.
Heating on
Heating off
°C
< 0
5
10
15
20
25
30
35
40
40
Heating on
< 5
< 32
10
41
15
50
20
59
25
68
30
77
35
86
40
95
45
104
45
104
Operation
Heating off
°F
< 41
50
59
68
77
86
95
104
113
113
61

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis